enow.com Web Search

  1. Ads

    related to: how to replace boiler drain valve 3 4 angle aluminum

Search results

  1. Results from the WOW.Com Content Network
  2. Sight glass - Wikipedia

    en.wikipedia.org/wiki/Sight_glass

    The gauge glass on a boiler needs to be inspected periodically and replaced if it is seen to have worn thin in the vicinity of the gland nuts, but a failure in service can still occur. Drivers are expected to carry two or three glass tubes, pre-cut to the required length, together with hemp or rubber seals, to replace the tubes on the road. [1]

  3. Boiler blowdown - Wikipedia

    en.wikipedia.org/wiki/Boiler_blowdown

    Several short blowdown events remove sludge more effectively than a single continuous blowdown. Shorter blowdown events cause less significant changes in boiler water level, and are safer during periods of high steam demand. [5] Bottom blowdown piping drains the lowest parts of the boiler so it can be used to drain the boiler for servicing.

  4. Piping and plumbing fitting - Wikipedia

    en.wikipedia.org/wiki/Piping_and_plumbing_fitting

    Valves stop (or regulate) the flow of liquids or gases. They are categorized by application, such as isolation, throttling, and non-return. Isolation valves temporarily disconnect part of a piping system to allow maintenance or repair, for example. Isolation valves are typically left in either a fully open or closed position.

  5. Isolation valve - Wikipedia

    en.wikipedia.org/wiki/Isolation_valve

    Isolation valves in a flare, relief or vent system must ensure that a flow path is always available to the flare or vent. These valves are secured in the open position (LO). Drain valves that connect a high pressure system to a low pressure drain system are locked in the closed position (LC) to prevent potential over-pressurisation of the drain ...

  6. Internally rifled boiler tubes - Wikipedia

    en.wikipedia.org/wiki/Internally_rifled_boiler_tubes

    The internally rifled (also known as ribbed) tubes are used in boilers and heat exchangers to improve the efficiency of heat transfer. The rifling imparts a centrifugal force to the flowing fluid (commonly a mixture of steam and water). This separates water from the mixture, forces the water towards the wall, and prevents formation of a steam ...

  7. ASME Boiler and Pressure Vessel Code - Wikipedia

    en.wikipedia.org/wiki/ASME_Boiler_and_Pressure...

    The ASME Boiler & Pressure Vessel Code (BPVC) is an American Society of Mechanical Engineers (ASME) standard that regulates the design and construction of boilers and pressure vessels. [1] The document is written and maintained by volunteers chosen for their technical expertise . [ 2 ]

  1. Ads

    related to: how to replace boiler drain valve 3 4 angle aluminum