enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Structural load - Wikipedia

    en.wikipedia.org/wiki/Structural_load

    Dead loads have small load factors, such as 1.2, because weight is mostly known and accounted for, such as structural members, architectural elements and finishes, large pieces of mechanical, electrical and plumbing (MEP) equipment, and for buildings, it's common to include a Super Imposed Dead Load (SIDL) of around 5 pounds per square foot ...

  3. Rail profile - Wikipedia

    en.wikipedia.org/wiki/Rail_profile

    The American Society of Civil Engineers (or ASCE) specified rail profiles in 1893 [20] for 5 lb/yd (2.5 kg/m) increments from 40 to 100 lb/yd (19.8 to 49.6 kg/m). Height of rail equaled width of foot for each ASCE tee-rail weight; and the profiles specified fixed proportion of weight in head, web and foot of 42%, 21% and 37%, respectively.

  4. Structural engineering theory - Wikipedia

    en.wikipedia.org/wiki/Structural_engineering_theory

    1.0 x Dead Load + 1.0 x Live Load. Different load cases would be used for different loading conditions. For example, in the case of design for fire a load case of 1.0 x Dead Load + 0.8 x Live Load may be used, as it is reasonable to assume everyone has left the building if there is a fire.

  5. Casing string - Wikipedia

    en.wikipedia.org/wiki/Casing_string

    A typical piece of casing might be described as 9-5/8" 53.5# P-110 LT&C Rg 3: specifying OD, weight per foot (53.5 lbm/ft thus 0.545-inch wall thickness and 8.535-inch inside diameter), steel strength (110,000 psi yield strength), end finish ("Long Threaded and Coupled"), and approximate length ("Range 3" usually runs between 40 and 42 feet).

  6. Allowable Strength Design - Wikipedia

    en.wikipedia.org/wiki/Allowable_Strength_Design

    Allowable Stress Design philosophy was left unsupported by AISC after the 9th edition of the manual which remained an acceptable reference design standard in evolving building codes (e.g. International Building Code by the International Code Council). This presented problems since new research, engineering concepts and design philosophy were ...

  7. Process duct work - Wikipedia

    en.wikipedia.org/wiki/Process_Duct_Work

    When tubes are used for these purposes they may be 10'-6" to 12 foot diameter, and up to 250 foot long, using up to 1/2" plate and ovaling ring stiffeners at 8 foot (to 20 foot centers). On one such project My firm added L8x8x3/4 at the top 45 degree location to stiffen the plate near the point of maximum stress for tubes (as per Timoshenko ...

  8. Design load - Wikipedia

    en.wikipedia.org/wiki/Design_load

    A crane's rated load is its Safe Working Load (SWL) and the design load (DL) is, (p 90) [1] = The dynamic lift factor for offshore cranes in the range 10 kN < SWL ≤ 2500 kN is not less than =.(p 84) [1] Thus for a crane with a SWL of 2000 kN (~200 tonne) its design load is not less than, = = The minimum breaking load (MBL) for the combined capacity of reeves of a steel wire hoisting rope ...

  9. Eurocode 1: Actions on structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_1:_Actions_on...

    EN 1991-1-1 gives design guidance and actions for the structural design of buildings and civil engineering works including some geotechnical aspects for the following subjects: Densities of construction materials and stored materials. Self-weight of construction works. Imposed loads for buildings.