enow.com Web Search

  1. Ads

    related to: sprinkler system double check valve diagram

Search results

  1. Results from the WOW.Com Content Network
  2. Double check valve - Wikipedia

    en.wikipedia.org/wiki/Double_check_valve

    The double check valve assembly is suitable for prevention of back pressure and back siphonage, but is not suitable for high hazard applications. It is commonly used on lawn irrigation, fire sprinkler [2] and combi-boiler systems. [3] If the hazard is higher, even a relatively low hazard such as using antifreeze in the fire sprinkler system ...

  3. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.

  4. Backflow - Wikipedia

    en.wikipedia.org/wiki/Backflow

    Regulations for these check valves specify the design capabilities of the valve used, according to the hazard. Category 2 contamination may be prevented by a single check valve, but category 3 requires a double check valve (these are manufactured as a convenient single unit, or even integrated into tap (faucet) fittings). Category 5 requires an ...

  5. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    Because certain combinations of check valve failure and/or system backpressure cause the relief valve to discharge, the device must be mounted in a location where the drain will not become flooded. An example of where backflow would harm the water supply is the use of well washing devices inside underground sewerage pumping stations.

  6. Atmospheric vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Atmospheric_vacuum_breaker

    It is usually constructed of brass and resembles a 90-degree elbow with a hood on its top to allow air to enter the water system if a siphon attempts to form. Inside this elbow is a poppet valve that is held "up" by the water pressure found in the system, closing the air entrance to the device. If the pressure in the "upstream side" is reduced ...

  7. Check valve - Wikipedia

    en.wikipedia.org/wiki/Check_valve

    Tilting-disc inconel check valve Check valve symbol on piping and instrumentation diagrams.The arrow shows the flow direction. Vertical lift check valve. A check valve, non-return valve, reflux valve, retention valve, foot valve, or one-way valve is a valve that normally allows fluid (liquid or gas) to flow through it in only one direction.

  8. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...

  9. Pressure vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Pressure_vacuum_breaker

    A pressure vacuum breaker (PVB) is a type of backflow prevention device, used to keep non-potable (or contaminated) water from entering the water supply. A PVB is similar to an atmospheric vacuum breaker (AVB), except that the PVB contains a spring-loaded poppet.

  1. Ads

    related to: sprinkler system double check valve diagram