NEMA 5-15P plug and NEMA 5-15R receptacle (different scales, blade spacing is 0.5 inches (12.7 mm) for both.) Each receptacle also accepts an ungrounded plug, whether polarized or unpolarized. Typical 5-15R residential receptacle 5-20R T-slot receptacle mounted with the hole for the ground pin at the top. The neutral connection is the wider T ...
This diagram was created with Inkscape, or with something else. This diagram uses embedded text that can be easily translated using a text editor. This version simplified from my table:NEMA receptacle pins.svg File:NEMA receptacle pins.svg by removing the bottom row's 3-phase power plugs and IEC computer connectors, as a way to simplify the table.
[1]: 112 They are needed to allow appliances with 3-wire power cords to plug into legacy ungrounded (two slot) receptacles found in older buildings. The use of such an adapter avoids the need to replace receptacles, but is potentially hazardous if the grounding tab is not connected to electrical ground.
1A1A44J5 - Unit 1, Assembly 1, Sub-Assembly 44, Jack 5 (J5 is a connector on a box referenced as A44) 1A1A45J333 - Unit 1, Assembly 1, Sub-Assembly 45, Jack 333 (J333 is a connector on a box referenced as A45) A cable connecting these two might be: 1A1W35 - In the assembly A1 is a cable called W35. Connectors on this cable would be designated:
For example, types 3, 4 and 6 are intended for outdoor use, but type 5 is not. A NEMA enclosure rating does not mean that it also meets the same UL enclosure rating. [2] NFPA is National Fire Protection Association, and NEC is National Electrical Code (U.S.A.)
The designations of the three contacts may vary. The IEC standards use the Line designations L1, L2 and L3. [15] NEMA standards use the Phase designations X, Y and Z. [16] Sockets intended for use with the American split Phase distribution system may have two line contacts and neutral. In this case the line designators X and Y are used. [16]
The NEMA 5-15 plug has two flat parallel blades like NEMA 1-15, and a ground (earth) pin. [49] It is rated 15 A at 125 volts. The ground pin is longer than the line and neutral blades, such that an inserted plug connects to ground before power.
A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...