enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    In a 12-lead ECG, all leads except the limb leads are assumed to be unipolar (aVR, aVL, aVF, V 1, V 2, V 3, V 4, V 5, and V 6). The measurement of a voltage requires two contacts and so, electrically, the unipolar leads are measured from the common lead (negative) and the unipolar lead (positive).

  3. Hexaxial reference system - Wikipedia

    en.wikipedia.org/wiki/Hexaxial_reference_system

    The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. The hexaxial reference system, better known as the Cabrera system, is a convention to present the extremity leads of the 12 lead electrocardiogram, [1] that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's ...

  4. Left axis deviation - Wikipedia

    en.wikipedia.org/wiki/Left_axis_deviation

    The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane.. In electrocardiography, left axis deviation (LAD) is a condition wherein the mean electrical axis of ventricular contraction of the heart lies in a frontal plane direction between −30° and −90°.

  5. Right axis deviation - Wikipedia

    en.wikipedia.org/wiki/Right_axis_deviation

    This refers to the appearance of leads I and II. If the QRS complex is negative in lead I and positive in lead II, the QRS complexes appear to be "reaching" to touch each other. This signifies right axis deviation. Conversely, if the QRS complex is positive in lead I and negative in lead II the leads have the appearance of "leaving" each other.

  6. Third-degree atrioventricular block - Wikipedia

    en.wikipedia.org/wiki/Third-degree_atrio...

    Since pacemaker correction of the third-degree block requires full-time pacing of the ventricles, a potential side effect is pacemaker syndrome, and may necessitate the use of a biventricular pacemaker, which has an additional 3rd lead placed in a vein in the left ventricle, providing more coordinated pacing of both ventricles.

  7. Sinus rhythm - Wikipedia

    en.wikipedia.org/wiki/Sinus_rhythm

    In humans, for an ECG to be described as showing a sinus rhythm, the shape of the P wave in each of the 12 standard ECG leads should be consistent with a "typical P vector" of +50° to +80°. [2] This means that the P wave should be: always positive in lead I, lead II, and aVF; always negative in lead aVR

  8. Einthoven's triangle - Wikipedia

    en.wikipedia.org/wiki/Einthoven's_triangle

    Lead II — This axis goes from the right arm to the left leg, with the negative electrode on the shoulder and the positive one on the leg. This results in a +60 degree angle of orientation. [4] = Lead III — This axis goes from the left shoulder (negative electrode) to the right or left leg (positive electrode). This results in a +120 degree ...

  9. Lewis lead - Wikipedia

    en.wikipedia.org/wiki/Lewis_lead

    Electrode placement for Lewis lead; RL electrode (green), not shown, remains on leg . A Lewis Lead (also called the S5 lead) is a modified ECG lead used to detect atrial flutter waves when atrial flutter is suspected clinically, based on signs and symptoms, but is not definitely demonstrated on the standard 12 lead ECG.