Search results
Results from the WOW.Com Content Network
Dose and dose rate are used to measure different quantities [1] in the same way that distance and speed are used to measure different quantities. When considering stochastic radiation effects, only the total dose is relevant; each incremental unit of dose increases the probability that the stochastic effect happens. [ 4 ]
In the 1930s the roentgen was the most commonly used unit of radiation exposure. This unit is obsolete and no longer clearly defined. This unit is obsolete and no longer clearly defined. One roentgen deposits 0.877 rad in dry air, 0.96 rad in soft tissue, [ 9 ] or anywhere from 1 to more than 4 rad in bone depending on the beam energy. [ 10 ]
The International Committee on Radiation Protection (ICRP) guidance states that if a personal dosimeter is worn on a position on the body representative of its exposure, assuming whole-body exposure, the value of Personal Dose Equivalent Hp(10), is sufficient to estimate an effective dose value suitable for radiological protection.
It is difficult to establish risks associated with low dose radiation. [7] One reason why is that a long period of time occurs from exposure to radiation and the appearance of cancer. [7] Also, there is a natural incidence of cancer. [7] It is difficult to determine whether increases in cancer in a population are caused by low dose radiation. [7]
Recognized effects of higher acute radiation doses are described in more detail in the article on radiation poisoning.Although the International System of Units (SI) defines the sievert (Sv) as the unit of radiation dose equivalent, chronic radiation levels and standards are still often given in units of millirems (mrem), where 1 mrem equals 1/1,000 of a rem and 1 rem equals 0.01 Sv.
The public information dose chart of the USA Department of Energy, shown here on the right, applies to USA regulation, which is based on ICRP recommendations. Note that examples in lines 1 to 4 have a scale of dose rate (radiation per unit time), whilst 5 and 6 have a scale of total accumulated dose.
Kerma, when applied to air, is equivalent to the legacy roentgen unit of radiation exposure, but there is a difference in the definition of these two units. The gray is defined independently of any target material, however, the roentgen was defined specifically by the ionisation effect in dry air, which did not necessarily represent the effect ...
External radiation dose quantities used in radiological protection. When the sievert is used to represent the stochastic effects of external ionizing radiation on human tissue, the radiation doses received are measured in practice by radiometric instruments and dosimeters and are called operational quantities. To relate these actual received ...