enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Cooling load temperature difference calculation method

    en.wikipedia.org/wiki/Cooling_load_temperature...

    The first of the cooling load factors used in this method is the CLTD, or the Cooling Load Temperature Difference. This factor is used to represent the temperature difference between indoor and outdoor air with the inclusion of the heating effects of solar radiation. [1] [5] The second factor is the CLF, or the cooling load factor.

  3. Ton of refrigeration - Wikipedia

    en.wikipedia.org/wiki/Ton_of_refrigeration

    The TR unit was developed during the 1880s. Its definition was set at the level of an industry standard in 1903, when Thomas Shipley of the York Manufacturing Company led the formation of an industry association (the Ice Machine Builders Association of the United States) along with standardization of several equipment specifications. [ 4 ]

  4. Template:Convert/list of units/energy - Wikipedia

    en.wikipedia.org/wiki/Template:Convert/list_of...

    Energy; system unit code (alternative) symbol or abbrev. notes sample default conversion combinations SI: yottajoule: YJ YJ 1.0 YJ (2.8 × 10 17 kWh) zettajoule: ZJ ZJ 1.0 ZJ (2.8 × 10 14 kWh)

  5. Cooling capacity - Wikipedia

    en.wikipedia.org/wiki/Cooling_capacity

    Cooling capacity is the measure of a cooling system's ability to remove heat. [1] It is equivalent to the heat supplied to the evaporator/boiler part of the refrigeration cycle and may be called the "rate of refrigeration" or "refrigeration capacity".

  6. Seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/Seasonal_energy_efficiency...

    The SEER rating of a unit is the cooling output during a typical cooling-season divided by the total electric energy input during the same period. The higher the unit's SEER rating the more energy efficient it is. In the U.S., the SEER is the ratio of cooling in British thermal units (BTUs) to the energy consumed in watt-hours.

  7. Cooling load - Wikipedia

    en.wikipedia.org/wiki/Cooling_load

    The cooling load [3] is calculated to select HVAC equipment that has the appropriate cooling capacity to remove heat from the zone. A zone is typically defined as an area with similar heat gains, similar temperature and humidity control requirements, or an enclosed space within a building with the purpose to monitor and control the zone's temperature and humidity with a single sensor e.g ...

  8. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [ 1 ] [ 2 ] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs.

  9. Energy conversion efficiency - Wikipedia

    en.wikipedia.org/wiki/Energy_conversion_efficiency

    Energy conversion efficiency (η) is the ratio between the useful output of an energy conversion machine and the input, in energy terms. The input, as well as the useful output may be chemical, electric power, mechanical work, light (radiation), or heat. The resulting value, η (eta), ranges between 0 and 1. [1] [2] [3]