enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Performance and modelling of AC transmission - Wikipedia

    en.wikipedia.org/wiki/Performance_and_modelling...

    For the lines of up to 60 km of length is so short, that the effect of shunt parameters are nearly undetectable throughout the line. And hence, these linear lines are categorized as Short Transmission Lines. For the lines of effective length in between 60 km to 250 km, the effect of shunt parameters can not be neglected.

  3. Transmission line - Wikipedia

    en.wikipedia.org/wiki/Transmission_line

    The transmission line model is an example of the distributed-element model. It represents the transmission line as an infinite series of two-port elementary components, each representing an infinitesimally short segment of the transmission line:

  4. Quite Universal Circuit Simulator - Wikipedia

    en.wikipedia.org/wiki/Quite_Universal_Circuit...

    The transmission line calculator can be used to design and analyze different types of transmission lines (e.g. microstrips, coaxial cables). A component library manager gives access to models for real life devices (e.g. transistors, diodes, bridges, opamps). These are usually implemented as macros. The library can be extended by the user.

  5. Short circuit ratio (electrical grid) - Wikipedia

    en.wikipedia.org/wiki/Short_circuit_ratio...

    The wind power plant, linked to the ERCOT grid through two 69kV transmission lines, worked efficiently when the SCR was around 4 during normal operations. However, when one of the 69kV lines was disconnected, the SCR dropped to 2 or less, leading to unfavorable, poorly damped, or un-damped voltage oscillations that were documented by PMUs at ...

  6. Power system simulation - Wikipedia

    en.wikipedia.org/wiki/Power_system_simulation

    A power-flow study calculates the loading on transmission lines and the power necessary to be generated at generating stations, given the required loads to be served. A short circuit study or fault analysis calculates the short-circuit current that would flow at various points of interest in the system under study, for short-circuits between ...

  7. Electric power transmission - Wikipedia

    en.wikipedia.org/wiki/Electric_power_transmission

    Although advanced lines can cost 2-4x more than steel, total reconductoring costs are less than half of a new line, given savings in time, land acquisition, permitting, and construction. [ 33 ] A reconductoring project in southeastern Texas upgraded 240 miles of transmission lines at a cost of $900,000 per mile, versus a 3,600-mile greenfield ...

  8. Stub (electronics) - Wikipedia

    en.wikipedia.org/wiki/Stub_(electronics)

    Radial stubs are a planar component that consists of a sector of a circle rather than a constant-width line. They are used with planar transmission lines when a low impedance stub is required. Low characteristic impedance lines require a wide line. With a wide line, the junction of the stub with the main line is not at a well-defined point.

  9. Characteristic impedance - Wikipedia

    en.wikipedia.org/wiki/Characteristic_impedance

    Applying the transmission line model based on the telegrapher's equations as derived below, [1] [2] the general expression for the characteristic impedance of a transmission line is: = + + where R {\displaystyle R} is the resistance per unit length, considering the two conductors to be in series ,