enow.com Web Search

  1. Ad

    related to: formulas to calculate power supply

Search results

  1. Results from the WOW.Com Content Network
  2. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    The plotted line represents the variation of instantaneous voltage (or current) with respect to time. This cycle repeats with a frequency that depends on the power system. In electrical engineering, three-phase electric power systems have at least three conductors carrying alternating voltages that are offset in time by one-third of the period ...

  3. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    In a symmetric three-phase power supply system, three conductors each carry an alternating current of the same frequency and voltage amplitude relative to a common reference, but with a phase difference of one third of a cycle (i.e., 120 degrees out of phase) between each. The common reference is usually connected to ground and often to a ...

  4. Load regulation - Wikipedia

    en.wikipedia.org/wiki/Load_regulation

    Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output). [1] [2]

  5. Maximum power transfer theorem - Wikipedia

    en.wikipedia.org/wiki/Maximum_power_transfer_theorem

    The red curve shows the power in the load, normalized relative to its maximum possible. The dark blue curve shows the efficiency η. The efficiency η is the ratio of the power dissipated by the load resistance R L to the total power dissipated by the circuit (which includes the voltage source's resistance of R S as well as R L):

  6. Power factor - Wikipedia

    en.wikipedia.org/wiki/Power_factor

    The presence of reactive power causes the real power to be less than the apparent power, and so, the electric load has a power factor of less than 1. A negative power factor (0 to −1) can result from returning active power to the source, such as in the case of a building fitted with solar panels when surplus power is fed back into the supply.

  7. Line regulation - Wikipedia

    en.wikipedia.org/wiki/Line_regulation

    The line regulation for an unregulated power supply is usually very high for a majority of operations, but this can be improved by using a voltage regulator. A low line regulation is always preferred. In practice, a well regulated power supply should have a line regulation of at most 0.1%. [1]

  8. Voltage regulation - Wikipedia

    en.wikipedia.org/wiki/Voltage_regulation

    In the voltage regulation formula, V no load is the voltage measured at the receiving end terminals when the receiving end is an open circuit. The entire short line model is an open circuit in this condition, and no current flows in an open circuit, so I = 0 A and the voltage drop across the line given by Ohm’s law V line drop = IZ line is 0 V.

  9. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  1. Ad

    related to: formulas to calculate power supply