Search results

  1. Results from the WOW.Com Content Network
  2. Template:NFPA 704 diamond/codes-overview - Wikipedia

    en.wikipedia.org/wiki/Template:NFPA_704_diamond/...

    Flammability 2: Must be moderately heated or exposed to relatively high ambient temperature before ignition can occur. Flash point between 38 and 93 °C (100 and 200 °F). E.g. diesel fuel code F: 3: Flammability 3: Liquids and solids that can be ignited under almost all ambient temperature conditions. Flash point between 23 and 38 °C (73 and ...

  3. Fire sprinkler - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler

    A fire sprinkler mounted on a ceiling. A fire sprinkler or sprinkler head is the component of a fire sprinkler system that discharges water when the effects of a fire have been detected, such as when a predetermined temperature has been exceeded. Fire sprinklers are extensively used worldwide, with over 40 million sprinkler heads fitted each year.

  4. Template:NFPA 704 - Wikipedia

    en.wikipedia.org/wiki/Template:NFPA_704

    This template produces a NFPA 704 safety square with optionally four hazard codes. It is designed to be used in a table. It is designed to be used in a table. Primary use is through {{ Chembox }} , the {{ NFPA 704 }} box and {{ OrganicBox complete }} (chemical data pages).

  5. NFPA 704 - Wikipedia

    en.wikipedia.org/wiki/NFPA_704

    "NFPA 704: Standard System for the Identification of the Hazards of Materials for Emergency Response" is a standard maintained by the U.S.-based National Fire Protection Association. First "tentatively adopted as a guide" in 1960, [ 1 ] and revised several times since then, it defines the " Safety Square " or " Fire Diamond " which is used to ...

  6. Fire sprinkler system - Wikipedia

    en.wikipedia.org/wiki/Fire_sprinkler_system

    In regions using NFPA 13 regulations, the time it takes water to reach the hydraulically remote sprinkler from the time that sprinkler is activated is limited to a maximum of 60 seconds. In industry practice, this is known as the "Maximum Time of Water Delivery".

  7. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    This page was last edited on 28 December 2024, at 14:21 (UTC).; Text is available under the Creative Commons Attribution-ShareAlike 4.0 License; additional terms may apply.

  8. Glossary of firefighting equipment - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_firefighting...

    Also known as a closet ladder, folding ladder or "pencil ladder." Required to be carried on pumpers by NFPA 1901. Automatic sprinkler System of pipes serving fire sprinklers, for automatically directing water to a fire when the sprinkler is heated to its actuation temperature (usually 155 deg F).

  9. Heat detector - Wikipedia

    en.wikipedia.org/wiki/Heat_detector

    Rate-of-Rise (ROR) heat detectors operate on a rapid rise in element temperature of 6.7 to 8.3°C (12.1 to 14.9°F) increase per minute, irrespective of the starting temperature. This type of heat detector can operate at a lower temperature fire condition than would be possible if the threshold were fixed.