enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Velocity time integral - Wikipedia

    en.wikipedia.org/wiki/Velocity_time_integral

    Velocity Time Integral is a clinical Doppler ultrasound measurement of blood flow, equivalent to the area under the velocity time curve. The product of VTI (cm/stroke) and the cross sectional area of a valve (cm2) yields a stroke volume (cm3/stroke), which can be used to calculate cardiac output.

  3. Stroke volume - Wikipedia

    en.wikipedia.org/wiki/Stroke_volume

    In cardiovascular physiology, stroke volume (SV) is the volume of blood pumped from the ventricle per beat. Stroke volume is calculated using measurements of ventricle volumes from an echocardiogram and subtracting the volume of the blood in the ventricle at the end of a beat (called end-systolic volume [note 1]) from the volume of blood just prior to the beat (called end-diastolic volume).

  4. quantium Medical Cardiac Output - Wikipedia

    en.wikipedia.org/wiki/Quantium_Medical_Cardiac...

    The signal can be altered also by shock or hypothermia states because of the peripheral vasoconstriction or arterial spasm. Usually, for calculating the stroke volume, the methods based on pulse wave analysis need previous and periodic calibrations that must be done in the same patient, which is a drawback.

  5. Cardiac output - Wikipedia

    en.wikipedia.org/wiki/Cardiac_output

    Major factors influencing cardiac output – heart rate and stroke volume, both of which are variable. [1]In cardiac physiology, cardiac output (CO), also known as heart output and often denoted by the symbols , ˙, or ˙, [2] is the volumetric flow rate of the heart's pumping output: that is, the volume of blood being pumped by a single ventricle of the heart, per unit time (usually measured ...

  6. Pressure–volume loop analysis in cardiology - Wikipedia

    en.wikipedia.org/wiki/Pressure–volume_loop...

    The net effect of these changes is that the width of the PV loop is increased (i.e., ventricular stroke volume is increased). However, ejection into the aorta (forward flow) is reduced. The increased ventricular stroke volume in this case includes the volume of blood ejected into the aorta as well as the volume ejected back into the left atrium.

  7. Electrical cardiometry - Wikipedia

    en.wikipedia.org/wiki/Electrical_Cardiometry

    Electrical cardiometry is a method based on the model of Electrical Velocimetry, and non-invasively measures stroke volume (SV), cardiac output (CO), and other hemodynamic parameters through the use of 4 surface ECG electrodes. Electrical cardiometry is a method trademarked by Cardiotronic, Inc., and is U.S. FDA approved for use on adults ...

  8. Aortic valve area calculation - Wikipedia

    en.wikipedia.org/wiki/Aortic_valve_area_calculation

    From these, it is easy to calculate the area (in cm 2) of the aortic valve by simply dividing the LV stroke volume (in cm 3) by the AV VTI (in cm) measured on the spectral Doppler display using continuous-wave Doppler. [citation needed] Stroke volume = 0.785(π/4) x Diameter 2 x VTI of LVOT Cross sectional area of LVOT = 0.785(π/4) x LVOT ...

  9. Rapid shallow breathing index - Wikipedia

    en.wikipedia.org/wiki/Rapid_shallow_breathing_index

    A RSBI score of less than 65 [3] indicating a relatively low respiratory rate compared to tidal volume is generally considered as an indication of weaning readiness. A patient with a rapid shallow breathing index (RSBI) of less than 105 has an approximately 80% chance of being successfully extubated, whereas an RSBI of greater than 105 virtually guarantees weaning failure. [4]