enow.com Web Search

  1. Ad

    related to: ups battery calculation

Search results

  1. Results from the WOW.Com Content Network
  2. Uninterruptible power supply - Wikipedia

    en.wikipedia.org/wiki/Uninterruptible_power_supply

    A large data-center-scale UPS being installed by electricians. An uninterruptible power supply (UPS) or uninterruptible power source is a type of continual power system that provides automated backup electric power to a load when the input power source or mains power fails.

  3. Ampere-hour - Wikipedia

    en.wikipedia.org/wiki/Ampere-hour

    4), the perceived energy capacity of a small UPS product that has multiple DC outputs at different voltages but is simply listed with a single ampere-hour rating, e.g., 8800 mAh, would be exaggerated by a factor of 3.75 compared to that of a sealed 12-volt lead-acid battery where the ampere-hour rating, e.g., 7 Ah, is based on the total output ...

  4. Depth of discharge - Wikipedia

    en.wikipedia.org/wiki/Depth_of_discharge

    Depth of discharge (DoD) is an important parameter appearing in the context of rechargeable battery operation. Two non-identical definitions can be found in commercial and scientific sources. The depth of discharge is defined as: the maximum fraction of a battery's capacity (given in Ah) which is removed from the charged battery on a regular basis.

  5. Peukert's law - Wikipedia

    en.wikipedia.org/wiki/Peukert's_law

    For example, consider a battery with a capacity of 200 Ah at the C 20 rate (C 20 means the 20-hour rate – i.e. the rate that will fully discharge the battery in 20 hours – which in this case is 10 A). If this battery is discharged at 10 A, it will last 20 hours, giving the rated capacity of 200 Ah.

  6. Battery room - Wikipedia

    en.wikipedia.org/wiki/Battery_room

    Battery rooms are also found in electric power plants and substations where reliable power is required for operation of switchgear, critical standby systems, and possibly black start of the station. [3] Often batteries for large switchgear line-ups are 125 V or 250 V nominal systems, and feature redundant battery chargers with independent power ...

  7. Backup battery - Wikipedia

    en.wikipedia.org/wiki/Backup_battery

    A valve-regulated lead-acid battery is a battery type that is popular in telecommunications network environments as a reliable backup power source. VRLA batteries are used in the outside plant at locations such as Controlled Environmental Vaults (CEVs), Electronic Equipment Enclosures (EEEs), and huts, and in uncontrolled structures such as ...

  8. Float voltage - Wikipedia

    en.wikipedia.org/wiki/Float_voltage

    Float voltage is the voltage at which a battery is maintained after being fully charged to maintain that capacity by compensating for self-discharge of the battery. [1] The voltage could be held constant for the entire duration of the cell's operation (such as in an automotive battery) or could be held for a particular phase of charging by the charger. [2]

  9. Diesel rotary uninterruptible power supply - Wikipedia

    en.wikipedia.org/wiki/Diesel_rotary...

    Most forms of uninterruptible power supply (UPS) can be either powered by battery or flywheel energy. These are ready for immediate use at the instant that the mains electricity fails, but the relatively small and finite amount of stored energy they contain makes them suitable for short periods of use, typically in the order of a few dozen minutes to a couple of hours depending on the actual load.

  1. Ad

    related to: ups battery calculation