Search results
Results from the WOW.Com Content Network
Wire Size: Amps: Wire Type: 3/0 Gauge: 200 Amps: Service entrance: 1/0 Gauge: 150 Amps: Service entrance and feeder wire: 3 Gauge: 100 Amps: Service entrance and feeder wire: 6 Gauge: 55 Amps: Feeder and large appliance wire: 8 Gauge: 40 Amps: Feeder and large appliance wire: 10 Gauge: 30 Amps: Dryers, appliances, and air conditioning: 12 Gauge ...
Get quick answers online, or reach a certified service provider or installer. And much more. Call us at (800) 222-7820. Find answers online to your Sub-Zero, Wolf, and Cove customer service questions here. Read about AWGElectrical Wire Size.
blower wire. Refer to the illustration. 4 Insert Romex® wire from the in-line or remote blower through the knockout and secure using an approved cord stain relief. 5 Connect white to blue, black to brown and green to the ground screw. Refer to the illustration. 6 Verify all wires are secure and not pinched between the cover, and install the ...
2) Insert 6" (152) Romex ® wire through the knockout opening. Secure the Romex ® wire to the electrical box with an appropriate connector. Use wire connectors or wire nuts approved by UL or C/UL. 3) Make electrical connections at the hood. Connect black to black, white to white and green/yellow to green or bare wire.
2 Lift the hood into position and insert Romex® wire(s) into the electrical knockout and secure with a UL or C/UL approved connector (not provided). 3 Secure the hood to the mounting strip and wall struc-ture with the provided screws and washers. 4 Connect the ducting to the transition and secure with duct sealing tape. CL A MOUNTING STRIP ...
(Romex®) into the electrical box. 2 Secure the electrical supply to the electrical box with a UL or C/UL approved connector (not provided). 3 Connect the green or bare ground wire to the green grounding screw. Use appropriate wire connectors (not provided) to connect white to white and black to black.
nect the green/bare wire to the ground screw. 2 Connect the blower supply to the power cord provided with the blower. Connect black to black, white to white, and the green/bare wire to the ground screw. 3 Verify all wires are secure and not pinched, and reinstall the box. 4 Plug the blower power cord into the receptacle inside the hood.
7 Lift the hood into position and insert Romex® wire(s) into the electrical knockout and secure with the provided connector. 8 Secure the hood to the mounting strip and wall structure with the provided screws and washers. 9 Connect the ducting to the transition and secure with duct sealing tape. 10 Reinstall the internal frame. Installation
1 Remove the connector from the end of the orange wire. 2 Connect the home supply. Connect black to black and connect the green/bare wire to the ground screw. 3 Connect the blower supply. Connect black to orange, all three white wires, and connect the green/bare wire to the ground screw. 4 Verify all wires are secure and not pinched, and ...
Remove the knockout above the home supply junction box, then insert the home power supply (Romex) into the electrical box. Refer to the illustration below. Secure the power supply to the electrical box with a UL or C/UL approved connector (not provided). Connect the green or bare ground wire to the green grounding screw.