enow.com Web Search

  1. Ad

    related to: 6 volt generator testing procedure

Search results

  1. Results from the WOW.Com Content Network
  2. Load bank - Wikipedia

    en.wikipedia.org/wiki/Load_bank

    A resistive/reactive inductive and/or capacitive load is often required to test solar inverters to ensure solar panels can be stopped from producing electricity in the event of a power outage. The resistive/reactive combination load banks are used to test the engine generator set at its rated power factor. In most cases this is 0.8 power factor ...

  3. Dielectric withstand test - Wikipedia

    en.wikipedia.org/wiki/Dielectric_withstand_test

    An insulation test set; in this pattern, a hand-cranked generator provides the high voltage and the scale is directly calibrated in megohms. Voltage withstand testing is done with a high-voltage source and voltage and current meters. A single instrument called a "pressure test set" or "hipot tester" is often used to perform this test.

  4. Electrical safety testing - Wikipedia

    en.wikipedia.org/wiki/Electrical_safety_testing

    An insulation resistance test (IR test) measures the electrical resistance of insulation by applying a voltage between two locations, and measuring the resultant current flow. Proper safety precautions must be taken when doing this test, such as exclusion zones, making sure no wires are exposed, and personal protective equipment is worn.

  5. Low voltage ride through - Wikipedia

    en.wikipedia.org/wiki/Low_voltage_ride_through

    For wind turbines, the FRT testing is described in the standard IEC 61400-21 (2nd edition August 2008). More detailed testing procedures are stated in the German guideline FGW TR3 (Rev. 22). Testing of devices with less than 16 Amp rated current is described in the EMC standard IEC 61000-4-11 [13] and for higher current devices in IEC 61000-4 ...

  6. IEC 61000-4-2 - Wikipedia

    en.wikipedia.org/wiki/IEC_61000-4-2

    The standard describes the output RC-network of the generator as having typical values of 330 Ω and 150 pF. The specified transient rise time (from 10% to 90% of the first peak) is 0.8 ns (±25%). The transient duration is not specified but for waveform verification currents should be measured in 30 ns and 60 ns for each of the test levels. [2]

  7. IEC 61000-4-5 - Wikipedia

    en.wikipedia.org/wiki/IEC_61000-4-5

    The "1.2/50 μs" generator is designed for insulation testing, and produces a high-voltage, low-current impulse into a high-impedance load. The output current of this generator is on the milliampere scale. [2] [5] The "8/20 μs" generator is designed for surge arrester testing, and produces a high-current surge into a low-impedance load. [2]

  8. AOL Mail

    mail.aol.com

    Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!

  9. High voltage - Wikipedia

    en.wikipedia.org/wiki/High_voltage

    Equipment and conductors that carry high voltage warrant special safety requirements and procedures. High voltage is used in electrical power distribution , in cathode-ray tubes , to generate X-rays and particle beams , to produce electrical arcs , for ignition, in photomultiplier tubes , and in high-power amplifier vacuum tubes , as well as ...

  1. Ad

    related to: 6 volt generator testing procedure