Search results
Results from the WOW.Com Content Network
Phasor notation (also known as angle notation) is a mathematical notation used in electronics engineering and electrical engineering.A vector whose polar coordinates are magnitude and angle is written . [13] can represent either the vector (, ) or the complex number + =, according to Euler's formula with =, both of which have magnitudes of 1.
Phasor diagram of Ferranti effect in Cable. In electrical engineering, the Ferranti effect is the increase in voltage occurring at the receiving end of a very long (> 200 km) AC electric power transmission line, relative to the voltage at the sending end, when the load is very small, or no load is connected. It can be stated as a factor, or as ...
Therefore, the phasor values of the pixels of an image with two lifetime components are distributed on a line connecting the phasors of τ 1 and τ 2. Fitting a line through these phasor points with slope (v) and interception (u) , will give two intersections with the semicircle that determine the lifetimes τ 1 and τ 2: [3]
Using a PMU, it is simple to detect abnormal waveform shapes. A waveform shape described mathematically is called a phasor.. A phasor measurement unit (PMU) is a device used to estimate the magnitude and phase angle of an electrical phasor quantity (such as voltage or current) in the electricity grid using a common time source for synchronization.
Fig. 2 illustrates the phasor diagram of the output voltages for a split-phase transformer. Since the two phasors do not define a unique direction of rotation for a revolving magnetic field, a split single-phase is not a two-phase system.
The vector sum of V R and the voltage drops equals V S, and it is apparent in the diagrams that V S does not equal V R in magnitude or phase angle. Voltage phasor diagrams for a short transmission line serving lagging, in-phase, and leading loads. The diagrams show that the phase angle of current in the line affects voltage regulation ...
Angle notation can easily describe leading and lagging current: . [1] In this equation, the value of theta is the important factor for leading and lagging current. As mentioned in the introduction above, leading or lagging current represents a time shift between the current and voltage sine curves, which is represented by the angle by which the curve is ahead or behind of where it would be ...
Phasor diagram showing 240 V delta and center-tapped phase (a–c) creating two 120 V pairs. Consider the low-voltage side of a 120/240 V high leg delta connected transformer, where the b phase is the high leg. The line-to-line voltage magnitudes are all the same: = = =.