enow.com Web Search

  1. Ad

    related to: a boiler interlock stops
  2. supplyhouse.com has been visited by 100K+ users in the past month

    • Meet the Team

      Get To Know the People Behind

      the Products at SupplyHouse.com!

    • Plumbing Supplies

      Including Fittings, Valves, Pumps,

      and More. Shop and Save Now!

Search results

  1. Results from the WOW.Com Content Network
  2. Interlock (engineering) - Wikipedia

    en.wikipedia.org/wiki/Interlock_(engineering)

    An interlock device is designed to allow a generator to provide backup power in such a way that it (a) prevents main and generator power to be connected at the same time, and (b) allows circuit breakers to operate normally without interference in the event of an overload condition. Most interlock devices for electrical systems employ a ...

  3. Trapped-key interlocking - Wikipedia

    en.wikipedia.org/wiki/Trapped-key_interlocking

    A key exchange block may only hold and release keys and may not have a bolt to interlock process equipment, or may be part of the interlock of a particular machine or device. This is a transfer block, part of a trapped-key interlock system. It does not have a bolt to stop operation of a device, but holds and releases other keys.

  4. Sail switch - Wikipedia

    en.wikipedia.org/wiki/Sail_switch

    A sail switch, vane switch or flow switch is a mechanical switch that is actuated on or off in response to the flow or non-flow of a fluid such as air or water. [1] A sail switch typically operates through the use of a paddle or a diaphragm which gets displaced due to the force of fluid or air moving past it.

  5. Safety instrumented system - Wikipedia

    en.wikipedia.org/wiki/Safety_instrumented_system

    One example of SIS is a temperature sensor that provides a signal to a controller, which compares the sensed process temperature to the desired temperature setpoint and sends a signal to an emergency on-off valve actuator which stops the flow of heating fluid to the process if the process temperature is exceeded by an unsafe margin.

  6. Glossary of boiler terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_boiler_terms

    erosion of a boiler's plates from the internal water space, particularly where there is a step inside the shell. This was a problem for early boilers made from lapped plates rather than butted plates, and gave rise to many boiler explosions. In later years it was a problem for the non-circular water drums of Yarrow boilers. Handhole

  7. Interlocking - Wikipedia

    en.wikipedia.org/wiki/Interlocking

    Railway interlocking is of British origin, where numerous patents were granted. In June 1856, John Saxby received the first patent for interlocking switches and signals. [2] [3]: 23–24 In 1868, Saxby (of Saxby & Farmer) [4] was awarded a patent for what is known today in North America as “preliminary latch locking”.

  8. Damper (flow) - Wikipedia

    en.wikipedia.org/wiki/Damper_(flow)

    A damper is a valve or plate that stops or regulates the flow of air inside a duct, chimney, VAV box, air handler, or other air-handling equipment. A damper may be used to cut off central air conditioning (heating or cooling) to an unused room, or to regulate it for room-by-room temperature and climate control - for example, in the case of ...

  9. Boiler stay - Wikipedia

    en.wikipedia.org/wiki/Boiler_stay

    A boiler stay is an internal structural element of a boiler. Where the shell of a boiler or other pressure vessel is made of cylindrical or (part) spherical elements, the internal pressure will be contained without distortion. However, flat surfaces of any significant size will distort under pressure, tending to bulge.

  1. Ad

    related to: a boiler interlock stops