enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Vacuum interrupter - Wikipedia

    en.wikipedia.org/wiki/Vacuum_interrupter

    After the 1970s, vacuum switches began to replace the minimal-oil switches in medium-voltage switchgear. In the early 1980s, SF6 switches and breakers were also gradually replaced by vacuum technology in medium-voltage application. As of 2018, a vacuum circuit-breaker had reached 145 kV with a short-circuit rating of 200 kA [4].

  3. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  4. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    A circuit breaker is an electrical safety device designed to protect an electrical circuit from damage caused by current in excess of that which the equipment can safely carry (overcurrent). Its basic function is to interrupt current flow to protect equipment and to prevent fire.

  5. Switchgear - Wikipedia

    en.wikipedia.org/wiki/Switchgear

    Circuit breakers and fuses disconnect when current exceeds a predetermined safe level. However they cannot sense other critical faults, such as unbalanced currents—for example, when a transformer winding contacts ground. By themselves, circuit breakers and fuses cannot distinguish between short circuits and high levels of electrical demand.

  6. Transient recovery voltage - Wikipedia

    en.wikipedia.org/wiki/Transient_Recovery_Voltage

    Examples of TRV waveshapes. A transient recovery voltage (TRV) for high-voltage circuit breakers is the voltage that appears across the terminals after current interruption. It is a critical parameter for fault interruption by a high-voltage circuit breaker, its characteristics (amplitude, rate of rise) can lead either to a successful current interruption or to a failure (called reignition or ...

  7. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    Automatically closing the breaker after it has tripped and stayed open for a brief amount of time, usually after 1 to 5 seconds, is a standard procedure. [ 5 ] Reclosers are often used as a key component in a smart grid , as they are effectively computer controlled switchgear which can be remotely operated and interrogated using supervisory ...

  8. Vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Vacuum_breaker

    A vacuum breaker is a device that prevents water from being siphoned backward in a direction it is not desired to go. They are commonly placed on a bibcock valve or toilet or urinal flush valve , in which application they can prevent hose or drainage water from back-siphoning into the public drinking water system.

  9. Substation - Wikipedia

    en.wikipedia.org/wiki/Substation

    A circuit breaker is used as a protection device to interrupt fault currents automatically, and may be used to switch loads on and off, or to cut off a line when power is flowing in the 'wrong' direction. When a large fault current flows through the circuit breaker, this is detected through the use of current transformers. The magnitude of the ...