enow.com Web Search

  1. Ad

    related to: microscope resolution calculator for computer camera

Search results

  1. Results from the WOW.Com Content Network
  2. 1951 USAF resolution test chart - Wikipedia

    en.wikipedia.org/wiki/1951_USAF_resolution_test...

    A 1951 USAF resolution test chart is a microscopic optical resolution test device originally defined by the U.S. Air Force MIL-STD-150A standard of 1951. The design provides numerous small target shapes exhibiting a stepped assortment of precise spatial frequency specimens. It is widely used in optical engineering laboratory work to analyze and ...

  3. Optical resolution - Wikipedia

    en.wikipedia.org/wiki/Optical_resolution

    For example, a 2-megapixel camera of 20-micrometre-square pixels will have worse resolution than a 1-megapixel camera with 8-micrometre pixels, all else being equal. For resolution measurement, film manufacturers typically publish a plot of Response (%) vs. Spatial Frequency (cycles per millimeter). The plot is derived experimentally.

  4. Diffraction-limited system - Wikipedia

    en.wikipedia.org/wiki/Diffraction-limited_system

    In optics, any optical instrument or system – a microscope, telescope, or camera – has a principal limit to its resolution due to the physics of diffraction. An optical instrument is said to be diffraction-limited if it has reached this limit of resolution performance. Other factors may affect an optical system's performance, such as lens ...

  5. Angular resolution - Wikipedia

    en.wikipedia.org/wiki/Angular_resolution

    Angular resolution. A series of images representing the magnification of M87* with an angular size of some microarcseconds, comparable to viewing a tennis ball on the Moon (magnification from top left corner counter−clockwise to the top right corner). Angular resolution describes the ability of any image-forming device such as an optical or ...

  6. Confocal microscopy - Wikipedia

    en.wikipedia.org/wiki/Confocal_microscopy

    Fluorescence and confocal microscopes operating principle. Confocal microscopy, most frequently confocal laser scanning microscopy (CLSM) or laser scanning confocal microscopy (LSCM), is an optical imaging technique for increasing optical resolution and contrast of a micrograph by means of using a spatial pinhole to block out-of-focus light in image formation. [1]

  7. Point spread function - Wikipedia

    en.wikipedia.org/wiki/Point_spread_function

    By virtue of the linearity property of optical non-coherent imaging systems, i.e., . Image(Object 1 + Object 2) = Image(Object 1) + Image(Object 2). the image of an object in a microscope or telescope as a non-coherent imaging system can be computed by expressing the object-plane field as a weighted sum of 2D impulse functions, and then expressing the image plane field as a weighted sum of the ...

  8. Field of view - Wikipedia

    en.wikipedia.org/wiki/Field_of_view

    Field of view is the area of the inspection captured on the camera’s imager. The size of the field of view and the size of the camera’s imager directly affect the image resolution (one determining factor in accuracy). Working distance is the distance between the back of the lens and the target object.

  9. Optical transfer function - Wikipedia

    en.wikipedia.org/wiki/Optical_transfer_function

    E.g. a microscope typically magnifies everything 10 to 100-fold, and a reflex camera will generally demagnify objects at a distance of 5 meter by a factor of 100 to 200. The resolution of a digital imaging device is not only limited by the optics, but also by the number of pixels, more in particular by their separation distance.

  1. Ad

    related to: microscope resolution calculator for computer camera