enow.com Web Search

  1. Ads

    related to: rtd sensor vs thermocouple light meter reading chart

Search results

  1. Results from the WOW.Com Content Network
  2. Resistance thermometer - Wikipedia

    en.wikipedia.org/wiki/Resistance_thermometer

    Resistance thermometers, also called resistance temperature detectors (RTDs), are sensors used to measure temperature. Many RTD elements consist of a length of fine wire wrapped around a heat-resistant ceramic or glass core but other constructions are also used. The RTD wire is a pure material, typically platinum (Pt), nickel (Ni), or copper ...

  3. List of temperature sensors - Wikipedia

    en.wikipedia.org/wiki/List_of_temperature_sensors

    The integrated circuit sensor may come in a variety of interfaces — analogue or digital; for digital, these could be Serial Peripheral Interface, SMBus/I 2 C or 1-Wire.. In OpenBSD, many of the I 2 C temperature sensors from the below list have been supported and are accessible through the generalised hardware sensors framework [3] since OpenBSD 3.9 (2006), [4] [5]: §6.1 which has also ...

  4. Temperature measurement - Wikipedia

    en.wikipedia.org/wiki/Temperature_measurement

    Resistance temperature detector (RTD) Pyrometer; Langmuir probes (for electron temperature of a plasma) Infrared thermometer; Other thermometers; One must be careful when measuring temperature to ensure that the measuring instrument (thermometer, thermocouple, etc.) is really the same temperature as the material that is being measured.

  5. Thermocouple - Wikipedia

    en.wikipedia.org/wiki/Thermocouple

    The table below describes properties of several different thermocouple types. Within the tolerance columns, T represents the temperature of the hot junction, in degrees Celsius. For example, a thermocouple with a tolerance of ±0.0025×T would have a tolerance of ±2.5 °C at 1000 °C. Each cell in the Color Code columns depicts the end of a ...

  6. Thermopile - Wikipedia

    en.wikipedia.org/wiki/Thermopile

    The two top thermocouple junctions are at temperature T 1 while the two bottom thermocouple junctions are at temperature T 2. The output voltage from the thermopile, ΔV , is directly proportional to the temperature differential, ΔT or T 1 - T 2 , across the thermal resistance layer and number of thermocouple junction pairs.

  7. Pirani gauge - Wikipedia

    en.wikipedia.org/wiki/Pirani_gauge

    An alternative to the Pirani gauge is the thermocouple gauge, which works on the same principle of detecting thermal conductivity of the gas by a change in temperature. In the thermocouple gauge, the temperature is sensed by a thermocouple rather than by the change in resistance of the heated wire.

  1. Ads

    related to: rtd sensor vs thermocouple light meter reading chart