enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Armoured cable - Wikipedia

    en.wikipedia.org/wiki/Armoured_cable

    It is known as SWA BS 5467 Cable and it has a voltage rating of 600/1000 V. [7] SWA cable can be referred to more generally as mains cable, armoured cable, power cable and booklet armoured cable. The name power cable, however, applies to a wide range of cables including 6381Y, NYCY, NYY-J and 6491X Cable.

  3. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  4. Economic optimization of electric conductors - Wikipedia

    en.wikipedia.org/wiki/Economic_optimization_of...

    There are several approaches to this which are all based upon these fundamental principles. The following standards cover the economics sizing of cables: IEC 60287-3-2.Electric cables - Calculation of the current rating - Part 3-2. [5] JCS 4521-1 Calculation of the Environmental Current Rating for the Electric Cables, Part 1. [6] AS/NZS 3008.1. ...

  5. Power cable - Wikipedia

    en.wikipedia.org/wiki/Power_cable

    It has advantages over armored building cable because it is lighter, easier to handle, and its sheathing is easier to work with. [10] Power cables use stranded copper or aluminum conductors, although small power cables may use solid conductors in sizes of up to 1/0. (For a detailed discussion on copper cables, see: Copper wire and cable.). The ...

  6. Electrical cable - Wikipedia

    en.wikipedia.org/wiki/Electrical_cable

    6 inch (15 cm) outside diameter, oil-cooled cables, traversing the Grand Coulee Dam throughout. An example of a heavy cable for power transmission. Fire test in Sweden, showing fire rapidly spreading through the burning of cable insulation, a phenomenon of great importance for cables used in some installations. 500,000 circular mil (254 mm 2) single conductor power cable

  7. Mineral-insulated copper-clad cable - Wikipedia

    en.wikipedia.org/wiki/Mineral-insulated_copper...

    Installation of MI cable takes more time than installation of a PVC-sheathed armoured cable of the same conductor size. [6] Installation of MICC is therefore a costly task. MI cable is only manufactured with ratings up to 1000 volts. The magnesium oxide insulation has a high affinity for moisture.

  8. Electrical wiring - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring

    Cables usually are secured with special fittings where they enter electrical apparatus; this may be a simple screw clamp for jacketed cables in a dry location, or a polymer-gasketed cable connector that mechanically engages the armour of an armoured cable and provides a water-resistant connection.

  9. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Several other types of wiring systems are used for building wiring in the United States; these include corrugated metal armored cable, mineral-insulated cable, other types of power cable, and various types of electrical conduit. In industrial applications cables may be laid in cable trays. Cable type TC is especially intended for use in tray ...