Chlorine pentafluoride (ClF 5) is made on a large scale by direct fluorination of chlorine with excess fluorine gas at 350 °C and 250 atm, and on a small scale by reacting metal chlorides with fluorine gas at 100–300 °C. It melts at −103 °C and boils at −13.1 °C.
Heat capacity, c p? J/(mol K) Liquid properties Std enthalpy change of formation, Δ f H o liquid: −687.0 kJ/mol Std Gibbs free energy of formation, Δ f G o liquid: −619.8 kJ/mol Standard molar entropy, S o liquid: 239.7 J/(mol K) Heat capacity, c p: 145. J/(mol K) Gas properties Std enthalpy change of formation, Δ f H o gas: −657. kJ ...
A mass chromatogram is a representation of mass spectrometry data as a chromatogram, where the x-axis represents time and the y-axis represents signal intensity. [1] The source data contains mass information; however, it is not graphically represented in a mass chromatogram in favor of visualizing signal intensity versus time.
Ion mobility spectrometry-mass spectrometry (IMS/MS or IMMS) is a technique where ions are first separated by drift time through some neutral gas under an applied electrical potential gradient before being introduced into a mass spectrometer. [43] Drift time is a measure of the collisional cross section relative to the charge of the ion.
Mass spectral interpretation is the method employed to identify the chemical formula, characteristic fragment patterns and possible fragment ions from the mass spectra. [1] [2] Mass spectra is a plot of relative abundance against mass-to-charge ratio. It is commonly used for the identification of organic compounds from electron ionization mass ...
Electron ionization mass spectrum of toluene. Note parent peak corresponding to molecular mass M = 92 (C 7 H 8 +) and highest peak at M-1 = 91 (C 7 H 7 +, quasi-stable tropylium cation). A mass spectrum is a histogram plot of intensity vs. mass-to-charge ratio (m/z) in a chemical sample, [1] usually acquired using an instrument called a mass ...
The DART ion source is a kind of gas-phase ionization, and it requires some sort of volatility of the analyte to support thermally assisted desorption of analyte ions. [14] This limits the size range of the molecules that can be analyzed by DART i.e. m/z 50 to 1200. [1] [15] DART-MS is capable of semi-quantitative and quantitative analysis. To ...
It is not possible to make an accurate identification of a particular molecule by gas chromatography or mass spectrometry alone. The mass spectrometry process normally requires a very pure sample while gas chromatography using a traditional detector (e.g. Flame ionization detector) cannot differentiate between multiple molecules that happen to ...