In firefighting, the policy of two-in, two-out refers to United States Occupational Safety and Health Administration (OSHA) policy 29 CFR 1910.134(g)(4)(i). [1] The respiratory protection standard requires that workers engaged in fighting interior structural fires work in a buddy system; at least two workers must enter the building together, so that they can monitor each other's whereabouts as ...
External access point for fire sprinkler and dry standpipe at a building in San Francisco, US Antique wet standpipe preserved at Edison and Ford Winter Estates. A standpipe or riser is a type of rigid water piping which is built into multi-story buildings in a vertical position, or into bridges in a horizontal position, to which fire hoses can be connected, allowing manual application of water ...
PASS (The basic steps for portable fire extinguisher use.) [6] Pull or Pin - Pull the pin at the top of the fire extinguisher (and immediately test the extinguisher). Aim - Aim the nozzle or outlet of the extinguisher at the base of the fire. Squeeze - Squeeze the handles of the extinguisher to begin discharging it.
Fire alarm control panels are usually found in an electrical or panel room. Fire alarm systems generally use visual and audio signalization to warn the occupants of the building. Some fire alarm systems may also disable elevators, which are unsafe to use during a fire under most circumstances. [1]
Fireproofing is rendering something (structures, materials, etc.) resistant to fire, or incombustible; or material for use in making anything fire-proof. [1] It is a passive fire protection measure. "Fireproof" or "fireproofing" can be used as a noun, verb or adjective; it may be hyphenated ("fire-proof").
(Attack line) A use classification of a fire fighting hose connected to output of a pump or other pressure source (e.g., gravity). Fire hose used to apply water or other fire fighting agent directly to a fire or burning substance. Typically of 2 + 1 ⁄ 2 inches (64 mm) diameter or less in the United States. Historically 1.5 inch hose was the ...
Fire control is the practice of reducing the heat output of a fire, reducing the area over which the fire exists, or suppressing or extinguishing the fire by depriving it of fuel, oxygen, or heat (see fire triangle). Fire prevention and control is the prevention, detection, and extinguishment of fires, including such secondary activities as ...
The NFPA 72 (National Fire Alarm and Signaling Code) is a standard published by the National Fire Protection Association every 3 years for installation of fire alarm systems and emergency communication systems in the United States.