enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Optical coherence tomography - Wikipedia

    en.wikipedia.org/wiki/Optical_coherence_tomography

    Ocular OCT retinal thickness map, right eye Time-domain OCT of the macular area of a retina at 800 nm, axial resolution 3 μm Spectral-domain OCT macula cross-section scan. Optical coherence tomography (OCT) is a technique for obtaining sub-surface images of translucent or opaque materials at a resolution equivalent to a low-power microscope.

  3. Optical coherence tomography angiography - Wikipedia

    en.wikipedia.org/wiki/Optical_Coherence...

    A short scan time prevents too much patient movement during signal acquisition. With the development of Fourier-domain OCT, spectral-domain OCT, and swept source signal acquisition time was greatly improved making OCTA possible. [40] OCTA scan time is now around three seconds, however, saccadic eye movement still causes a low signal-to-noise ratio.

  4. Doppler optical coherence tomography - Wikipedia

    en.wikipedia.org/wiki/Doppler_optical_coherence...

    Doppler Optical Coherence Tomography is an extension of OCT, where it combines the Doppler effect principle to achieve high resolution tomographic images in biological tissues. And because of its high resolution and velocity sensitivity, there are many applications in the medical field. The basic phenomenon of Doppler OCT can be explained below.

  5. OCT Biomicroscopy - Wikipedia

    en.wikipedia.org/wiki/OCT_Biomicroscopy

    OCT Biomicroscopy is the use of optical coherence tomography (OCT) in place of slit lamp biomicroscopy to examine the transparent axial tissues of the eye. [1] Traditionally, ophthalmic biomicroscopy has been completed with a slit lamp biomicroscope that uses slit beam illumination and an optical microscope to enable stereoscopic, magnified, cross-sectional views of transparent tissues in the ...

  6. Fundus photography - Wikipedia

    en.wikipedia.org/wiki/Fundus_photography

    Normal fundus photographs of the left eye (left image) and right eye (right image), seen from front so that left in each image is to the person's right. Each fundus has no sign of disease or pathology. The gaze is into the camera, so in each picture the macula is in the center of the image, and the optic disk is located towards the nose. Both ...

  7. Retinal scan - Wikipedia

    en.wikipedia.org/wiki/Retinal_scan

    A retinal scan is performed by casting an unperceived beam of low-energy infrared light into a person’s eye as they look through the scanner's eyepiece. This beam of light traces a standardized path on the retina. Because retinal blood vessels absorb light more readily than the surrounding tissue, the amount of reflection varies during the scan.

  8. Optical transfer function - Wikipedia

    en.wikipedia.org/wiki/Optical_transfer_function

    While optical resolution, as commonly used with reference to camera systems, describes only the number of pixels in an image, and hence the potential to show fine detail, the transfer function describes the ability of adjacent pixels to change from black to white in response to patterns of varying spatial frequency, and hence the actual ...

  9. Speckle variance optical coherence tomography - Wikipedia

    en.wikipedia.org/wiki/Speckle_variance_optical...

    OCT can be used to capture functional images of blood flow, a technique known as optical coherence tomography angiography (OCT-A). SV-OCT is one method for OCT-A that uses the variance of consecutively acquired images to detect flow at the micron scale. SV-OCT can be used to measure the microvasculature of tissue.