enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Rating plate - Wikipedia

    en.wikipedia.org/wiki/Rating_plate

    The plate frequently contains the names of the machine and its manufacturer, so the rating plate is often called a name plate (hence the term "nameplate capacity" for a generator), although many devices carry separate nameplates and rating plates. [1] For an electric machine, the power rating is the number on its rating plate and corresponds to ...

  3. Nameplate capacity - Wikipedia

    en.wikipedia.org/wiki/Nameplate_capacity

    Nameplate capacity, also known as the rated capacity, nominal capacity, installed capacity, maximum effect or gross capacity, [1] is the intended full-load sustained output of a facility such as a power station, [2] [3] electric generator, a chemical plant, [4] fuel plant, mine, [5] metal refinery, [6] and many others.

  4. Power rating - Wikipedia

    en.wikipedia.org/wiki/Power_rating

    For every hour of operation at the service-factor-adjusted power rating, a motor loses two to three hours of life at nominal power, i.e. its service life is reduced to less than half for continued operation at this level. [4] [10] The service factor is defined in the ANSI/NEMA MG 1 standard, [11] and is generally used in the United States. [12]

  5. Capacity factor - Wikipedia

    en.wikipedia.org/wiki/Capacity_factor

    The theoretical maximum energy output of a given installation is defined as that due to its continuous operation at full nameplate capacity over the relevant period. The capacity factor can be calculated for any electricity producing installation, such as a fuel consuming power plant or one using renewable energy , such as wind, the sun or ...

  6. Nominal power (photovoltaic) - Wikipedia

    en.wikipedia.org/wiki/Nominal_power_(photovoltaic)

    In the context of domestic PV installations, the kilowatt (symbol kW) is the most common unit for nominal power, for example P peak = 1 kW. Colloquial English sometimes conflates the quantity power and its unit by using the non-standard label watt-peak (symbol W p), possibly prefixed as in kilowatt-peak (kW p), megawatt-peak (MW p), etc.

  7. Orders of magnitude (power) - Wikipedia

    en.wikipedia.org/wiki/Orders_of_magnitude_(power)

    1.00 × 10 4 W eco: average power consumption per person in the United States in 2008 (87,216 kWh/year) 1.4 × 10 4 W tech: average power consumption of an electric car on EPA's Highway test schedule [25] [26] 1.45 × 10 4 W astro: power per square metre received from the Sun at Mercury's orbit at perihelion: 1.6–3.2 × 10 4 W

  8. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    Due to high cost of a generator, a set of sensors and limiters will trigger the alarm when the generator approaches the capability-set boundary and, if no action is taken by the operator, will disconnect the generator from the grid. [3] D-curve expands with cooling. The D-curve for a particular generator can be expanded by improved cooling.

  9. Engine–generator - Wikipedia

    en.wikipedia.org/wiki/Engine–generator

    An engine–generator is the combination of an electrical generator and an engine (prime mover) mounted together to form a single piece of equipment. This combination is also called an engine–generator set or a gen-set. In many contexts, the engine is taken for granted and the combined unit is simply called a generator. An engine–generator ...