  2. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    For voltage ratios that don't exceed about 3:1, an autotransformer is cheaper, lighter, smaller, and more efficient than an isolating (two-winding) transformer of the same rating. [3] Large three-phase autotransformers are used in electric power distribution systems, for example, to interconnect 220 kV and 33 kV sub-transmission networks or ...

  3. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    Delta-wye transformers introduce a 30, 150, 210, or 330 degree phase shift. [3] Thus they cannot be paralleled with wye-wye (or delta-delta) transformers. However, they can be paralleled with identical configurations and some different configurations of other delta-wye (or wye-delta with some attention) transformers.

  4. Transformer - Wikipedia

    en.wikipedia.org/wiki/Transformer

    In electrical engineering, a transformer is a passive component that transfers electrical energy from one electrical circuit to another circuit, or multiple circuits.A varying current in any coil of the transformer produces a varying magnetic flux in the transformer's core, which induces a varying electromotive force (EMF) across any other coils wound around the same core.

  5. Voltage transformer - Wikipedia

    en.wikipedia.org/wiki/Voltage_transformer

    Transformer winding primary (usually high-voltage) connecting wires are of many types. They may be labeled as H 1, H 2 (sometimes H 0 if it is internally designed to be grounded) and X 1, X2 and sometimes an X 3 tap may be present. Sometimes a second isolated winding (Y 1, Y 2, Y 3) (and third (Z 1, Z 2, Z 3) may also be available on the same ...

  6. Isolation transformer - Wikipedia

    en.wikipedia.org/wiki/Isolation_transformer

    A 230 V isolation transformer A simple 1:1 isolation transformer with an extra dielectric barrier and an electrostatic shield between primary and secondary. The grounded shield prevents capacitive coupling between primary and secondary windings.

  7. Distribution transformer - Wikipedia

    en.wikipedia.org/wiki/Distribution_transformer

    Distribution transformers typically have ratings less than 200 kVA, [3] although some national standards allow units up to 5000 kVA to be described as distribution transformers. Since distribution transformers are energized 24 hours a day (even when they don't carry any load), reducing iron losses is vital in their design.

  8. Scott-T transformer - Wikipedia

    en.wikipedia.org/wiki/Scott-T_transformer

    Assuming the desired voltage is the same on the two and three phase sides, the Scott-T transformer connection (shown right) consists of a centre-tapped 1:1 ratio main transformer, T1, and a √ 3 /2(≈86.6%) ratio teaser transformer, T2. The centre-tapped side of T1 is connected between two of the phases on the three-phase side.

  9. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    The transformer's impedance should not be too low for desired maximum fault current. Impedance can be added after the secondaries are summed to limit maximum fault currents (the 3I o path). [6] A combination of Y (wye or star), delta, and zigzag windings may be used to achieve a vector phase shift. For example, an electrical network may have a ...