Search results
Results from the WOW.Com Content Network
Low-pressure coolant injection is the emergency injection mode of the Residual Heat Removal (RHR) system. LPCI can be operated at reactor vessel pressures below 375 psi. LPCI consists of several pumps which are capable of injecting up to 150,000 L/min (40,000 US gal/min) of water into the reactor.
The essential service water system (ESWS) circulates the water that cools the plant's heat exchangers and other components before dissipating the heat into the environment. Because this includes cooling the systems that remove decay heat from both the primary system and the spent fuel rod cooling ponds, the ESWS is a safety-critical system. [ 7 ]
The Fukushima Daiichi nuclear disaster in 2011 occurred due to a loss-of-coolant accident. The circuits that provided electrical power to the coolant pumps failed causing a loss-of-core-cooling that was critical for the removal of residual decay heat which is produced even after active reactors are shut down and nuclear fission has ceased.
Units 1 through 4 at the plant. At the time of the earthquake, Unit 4 had been shut down for shroud replacement and refueling since 29 November 2010. [1] [2] All 548 fuel assemblies had been transferred in December 2010 from the reactor to the spent fuel pool on an upper floor of the reactor building [3] where they were held in racks containing boron to damp down any nuclear reaction. [4]
The removal of heat from nuclear reactors is an essential step in the generation of energy from nuclear reactions.In nuclear engineering there are a number of empirical or semi-empirical relations used for quantifying the process of removing heat from a nuclear reactor core so that the reactor operates in the projected temperature interval that depends on the materials used in the construction ...
In events where the reactor coolant pressure boundary remains intact, the Isolation Condenser System (ICS) is used to remove decay heat from the reactor and transfer it outside containment. The ICS system is a closed loop system that connects the reactor pressure vessel to a heat exchanger located in the upper elevation of the reactor building.
Goo had received a township occupancy permit in September 2022 for the 26,700-square-foot (2,480-square-meter) building as a retail location for a “smoke shop/vape store” that would sell ...
Most nuclear power plants feature a containment building whose role is to be the ultimate barrier, as per the defense-in-depth principle, against the release of radionuclides in the environment during accidents involving partial or total reactor core damage, that is, in which the integrity of the nuclear fuel (first barrier) is lost.