Search results
Results from the WOW.Com Content Network
A VRU works by compressing the flash gas that is produced in storage tanks and other units to be put into a pipeline. A basic VRU is made up of a scrubber, compressor, and a switch. Once the pressure in the tank reaches the set-point, the switch kicks on the compressor and sends the vapor to a scrubber where the liquid portion is separated out ...
When the sensor is dipped in ethanol and then taken out to evaporate, the instrument shows progressively lower temperature as the ethanol evaporates. Rain evaporating after falling on hot pavement Evaporation is a type of vaporization that occurs on the surface of a liquid as it changes into the gas phase. [ 1 ]
Outgassing (sometimes called offgassing, particularly when in reference to indoor air quality) is the release of a gas that was dissolved, trapped, frozen, or absorbed in some material. [1] Outgassing can include sublimation and evaporation (which are phase transitions of a substance into a gas), as well as desorption , seepage from cracks or ...
MAP sensors measure absolute pressure. Boost sensors or gauges measure the amount of pressure above a set absolute pressure. That set absolute pressure is usually 100 kPa. This is commonly referred to as gauge pressure. Boost pressure is relative to absolute pressure - as one increases or decreases, so does the other.
Gasoline should ideally be stored in an airtight container (to prevent oxidation or water vapor mixing in with the gas) that can withstand the vapor pressure of the gasoline without venting (to prevent the loss of the more volatile fractions) at a stable cool temperature (to reduce the excess pressure from liquid expansion and to reduce the ...
If the car's own vapor recovery system is working properly, then the Stage II nozzle will only be vacuuming normal fresh air and depositing that into the gas station's underground fuel storage tanks. That ends up causing evaporation of fuel vapors into the atmosphere, because too much pressure builds up in those fuel storage tanks.
The compression ratio in a MVR unit does not usually exceed 1.8. At a compression ratio of 1.8, if the evaporation is performed at atmospheric pressure (0.101 MPa), the condensation pressure after compression will be 0.101 x 1.8 = 0.1818 [MPa]. At this pressure, the condensation temperature of the water vapor at the heat exchanger will be 390 K.
In most automotive fuel gauges such resistors are on the inward side of the gauge, i.e., inside the fuel tank. Sending current through such a resistor has a fire hazard and an explosion risk associated with it. These resistance sensors are also showing an increased failure rate with the incremental additions of alcohol in automotive gasoline ...