enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 scfm when C v = 1.0, 2 psia input).

  3. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  4. Pressure coefficient - Wikipedia

    en.wikipedia.org/wiki/Pressure_coefficient

    of zero indicates the pressure is the same as the freestream pressure. C p {\displaystyle C_{p}} of one corresponds to the stagnation pressure and indicates a stagnation point . the most negative values of C p {\displaystyle C_{p}} in a liquid flow can be summed to the cavitation number to give the cavitation margin.

  5. Volumetric flow rate - Wikipedia

    en.wikipedia.org/wiki/Volumetric_flow_rate

    The area required to calculate the volumetric flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface. The vector area is a combination of the magnitude of the area through which the volume passes through, A , and a unit vector normal to the area, n ^ {\displaystyle {\hat {\mathbf {n} }}} .

  6. Orifice plate - Wikipedia

    en.wikipedia.org/wiki/Orifice_plate

    Orifice plate showing vena contracta. An orifice plate is a thin plate with a hole in it, which is usually placed in a pipe. When a fluid (whether liquid or gaseous) passes through the orifice, its pressure builds up slightly upstream of the orifice [1] but as the fluid is forced to converge to pass through the hole, the velocity increases and the fluid pressure decreases.

  7. Flow measurement - Wikipedia

    en.wikipedia.org/wiki/Flow_measurement

    The Dall tube is a shortened version of a Venturi meter, with a lower pressure drop than an orifice plate. As with these flowmeters the flow rate in a Dall tube is determined by measuring the pressure drop caused by restriction in the conduit. The pressure differential is typically measured using diaphragm pressure transducers with digital readout.

  8. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    onlineflow.de, webpage Online calculator for conversion of volume, mass and molar flows (SCFM, MMSCFD, Nm3/hr, kg/s, kmol/hr and more) ACFM versus SCFM for ASME AG-1 HEPA Filters; SCFM (Standard CFM) vs. ACFM (Actual CFM) (Specifically for air flows only) "Standard conditions for gases" from the IUPAC Gold Book. "Standard pressure" from the ...

  9. Dynamic pressure - Wikipedia

    en.wikipedia.org/wiki/Dynamic_pressure

    Dynamic pressure is one of the terms of Bernoulli's equation, which can be derived from the conservation of energy for a fluid in motion. [1] At a stagnation point the dynamic pressure is equal to the difference between the stagnation pressure and the static pressure, so the dynamic pressure in a flow field can be measured at a stagnation point ...