Search results
Results from the WOW.Com Content Network
Chromatographic peak resolution is given by = + where t R is the retention time and w b is the peak width at baseline. The bigger the time-difference and/or the smaller the bandwidths, the better the resolution of the compounds.
In liquid chromatography, the mobile phase velocity is taken as the exit velocity, that is, the ratio of the flow rate in ml/second to the cross-sectional area of the ‘column-exit flow path.’ For a packed column, the cross-sectional area of the column exit flow path is usually taken as 0.6 times the cross-sectional area of the column.
The partition coefficient principle has been applied in paper chromatography, thin layer chromatography, gas phase and liquid–liquid separation applications. The 1952 Nobel Prize in chemistry was earned by Archer John Porter Martin and Richard Laurence Millington Synge for their development of the technique, which was used for their ...
The valley definition defines ΔM as the closest spacing of two peaks of equal intensity with the valley (lowest value of signal) between them less than a specified fraction of the peak height. Typical values are 10% or 50%. The value obtained from a 5% peak width is roughly equivalent to a 10% valley. [1]
The spot capacity (analogous to peak capacity in HPLC) can be increased by developing the plate with two different solvents, using two-dimensional chromatography. [8] The procedure begins with development of a sample loaded plate with first solvent. After removing it, the plate is rotated 90° and developed with a second solvent.
The retention time is the time from the start of signal detection to the time of the peak height of the Gaussian curve. From the variables in the figure above, the resolution, plate number, and plate height of the column plate model can be calculated using the equations: Resolution (R s): R s = 2(t RB – t RA)/(w B + w A), where:
An electropherogram (also called electrophoretogram, sequencing chromatogram, EPG, and e-gram) is a record or chart produced when electrophoresis is used in an analytical technique, primarily in the fields of forensic biology, molecular biology, and biochemistry. [1]
On the other hand, another kind of analysis is to also measure the duration of the perceived odour to compute peak areas. The peak areas are known as Charm values in the CharmAnalysis developed in 1984 by Acree and co-workers. [7] [8] The former can then be interpreted as the peak height of the latter. Because the odour threshold of a compound ...