enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. R-value (insulation) - Wikipedia

    en.wikipedia.org/wiki/R-value_(insulation)

    For comparison, phenolic foam insulation has a k-value of around 0.018 W/(m⋅K), [23] while wood varies anywhere from 0.15 to 0.75 W/(m⋅K), and steel has a k-value of approximately 50.0 W/(m⋅K). These figures vary from product to product, so the UK and EU have established a 90/90 standard which means that 90% of the product will conform to ...

  3. Tog (unit) - Wikipedia

    en.wikipedia.org/wiki/Tog_(unit)

    The basic unit of insulation coefficient is the R SI, (1 m 2 ⋅K/W). 1 tog = 0.1 R SI. There is also a US clothing unit, the clo , equivalent to 0.155 R SI or 1.55 tog, described in ASTM D-1518. [ 7 ]

  4. Thermal conductivity and resistivity - Wikipedia

    en.wikipedia.org/wiki/Thermal_conductivity_and...

    The construction industry makes use of measures such as the R-value (resistance) and the U-value (transmittance or conductance). Although related to the thermal conductivity of a material used in an insulation product or assembly, R- and U-values are measured per unit area, and depend on the specified thickness of the product or assembly. [note 2]

  5. Vacuum insulated panel - Wikipedia

    en.wikipedia.org/wiki/Vacuum_insulated_panel

    This means that VIPs have about one-fifth the thermal conductivity of conventional insulation, and therefore about five times the thermal resistance per unit thickness. Based on a typical k-value of 0.007 W/(m·K), the R-value of a typical 25-millimetre-thick (1 in) VIP would be 3.5 m 2 ·K/W (20 h·ft 2 ·°F/BTU). To provide the same R-value ...

  6. Thermal transmittance - Wikipedia

    en.wikipedia.org/wiki/Thermal_transmittance

    Although the concept of U-value (or U-factor) is universal, U-values can be expressed in different units. In most countries, U-value is expressed in SI units, as watts per square metre-kelvin: W/(m 2 ⋅K) In the United States, U-value is expressed as British thermal units (Btu) per hour-square feet-degrees Fahrenheit: Btu/(h⋅ft 2 ⋅°F)

  7. List of thermal conductivities - Wikipedia

    en.wikipedia.org/wiki/List_of_thermal_conductivities

    Let K 0 is the normal conductivity at one bar (10 5 N/m 2) pressure, K e is its conductivity at special pressure and/or length scale. Let d is a plate distance in meters, P is an air pressure in Pascals (N/m 2 ), T is temperature Kelvin, C is this Lasance constant 7.6 ⋅ 10 −5 m ⋅ K/N and PP is the product P ⋅ d/T .

  8. Heat transfer coefficient - Wikipedia

    en.wikipedia.org/wiki/Heat_transfer_coefficient

    Architects and engineers call the resulting values either the U-Value or the R-Value of a construction assembly like a wall. Each type of value (R or U) are related as the inverse of each other such that R-Value = 1/U-Value and both are more fully understood through the concept of an overall heat transfer coefficient described in lower section ...

  9. Thermal conductance and resistance - Wikipedia

    en.wikipedia.org/wiki/Thermal_conductance_and...

    The SI unit of absolute thermal resistance is kelvins per watt (K/W) or the equivalent degrees Celsius per watt (°C/W) – the two are the same since the intervals are equal: ΔT = 1 K = 1 °C. The thermal resistance of materials is of great interest to electronic engineers because most electrical components generate heat and need to be cooled.