enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Goldmann Applanation Tonometer - Wikipedia

    en.wikipedia.org/wiki/Goldmann_Applanation_Tonometer

    Goldmann applanation tonometer is based on the Imbert–Fick principle, which states that for a dry thin-walled sphere, the pressure (P) inside the sphere equals the force (F) necessary to flatten its surface divided by the area (A) of flattening (i.e. P = F/A).

  3. Ocular tonometry - Wikipedia

    en.wikipedia.org/wiki/Ocular_tonometry

    The Perkins tonometer is a type of portable applanation tonometer, which may be useful in children, anesthetised patients who need to lie flat, or patients unable to co-operate with a sitting slit lamp examination, that yields clinical results comparable to the Goldmann. [8]

  4. Schiøtz tonometer - Wikipedia

    en.wikipedia.org/wiki/Schiøtz_tonometer

    The Schiotz tonometer consists of a curved footplate which is placed on the cornea of a supine patient. A weighted plunger attached to the footplate sinks into the cornea. A scale then gives a reading depending on how much the plunger sinks into the cornea, and a conversion table converts the scale reading into IOP measured in mmHg.

  5. Imbert-Fick law - Wikipedia

    en.wikipedia.org/wiki/Imbert-Fick_law

    Armand Imbert (1850-1922) and Adolf Fick (1829-1901) both demonstrated, independently of each other, that in ocular tonometry the tension of the wall can be neutralized when the application of the tonometer produces a flat surface instead of a convex one, and the reading of the tonometer (P) then equals (T) the IOP," whence all forces cancel each other.

  6. Intraocular pressure - Wikipedia

    en.wikipedia.org/wiki/Intraocular_pressure

    A patient in front of a tonometer. Intraocular pressure (IOP) is the fluid pressure inside the eye. Tonometry is the method eye care professionals use to determine this. IOP is an important aspect in the evaluation of patients at risk of glaucoma. [1] Most tonometers are calibrated to measure pressure in millimeters of mercury .

  7. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    This is called a limited calibration. But if the final measurement requires 10% accuracy, then the 3% gauge never can be better than 3.3:1. Then perhaps adjusting the calibration tolerance for the gauge would be a better solution. If the calibration is performed at 100 units, the 1% standard would actually be anywhere between 99 and 101 units.

  8. Peripheral Arterial Tone - Wikipedia

    en.wikipedia.org/wiki/Peripheral_Arterial_Tone

    The PAT signal is a form of pulse wave amplitude measured by incorporating both a unified pressure field and a specific isosbestic wavelength.Applying a uniform pressure field around the measured surface releases arterial wall motion restriction, magnifies the dynamic range of the recorded signal, and prevents the distention of the veins distal to the site of pressure application.

  9. Color calibration - Wikipedia

    en.wikipedia.org/wiki/Color_calibration

    For calibrating the monitor a colorimeter is attached flat to the display's surface, shielded from all ambient light. The calibration software sends a series of color signals to the display and compares the values that were actually sent against the readings from the calibration device. This establishes the current offsets in color display.