Since the final exhaust from a condensing boiler has a lower temperature than the exhaust from an atmospheric boiler 38 °C (100 °F) vs. 204 °C (400 °F) a mechanical fan is always required to expel it, with the additional benefit of allowing the use of low-temperature exhaust piping (typically PVC in domestic applications) without insulation ...
The EU standard test conditions for an air source heat pump is at dry-bulb temperature of 20 °C (68 °F) for and 7 °C (44.6 °F) for . [9] Given sub-zero European winter temperatures, real world heating performance is significantly poorer than such standard COP figures imply.
The actual vapor power cycle differs from the ideal Rankine cycle because of irreversibilities in the inherent components caused by fluid friction and heat loss to the surroundings; fluid friction causes pressure drops in the boiler, the condenser, and the piping between the components, and as a result the steam leaves the boiler at a lower ...
Vapor-compression refrigeration [6] For comparison, a simple stylized diagram of a heat pump's vapor-compression refrigeration cycle: 1) condenser, 2) expansion valve, 3) evaporator, 4) compressor (Note that this diagram is flipped vertically and horizontally compared to the previous one) [7] Temperature–entropy diagram of the vapor-compression cycle.
A condensate pump is a specific type of pump used to pump the condensate produced in an HVAC (heating or cooling), refrigeration, condensing boiler furnace, or steam system. [ 1 ] Applications
Higher heating value (HHV) is determined by bringing all the products of combustion back to the original pre-combustion temperature, and in particular condensing any vapor produced. This is the same as the thermodynamic heat of combustion .
In general, heat pumps work most efficiently (that is, the heat output produced for a given energy input) when the difference between the heat source and the heat sink is small. When using a heat pump for space or water heating, therefore, the heat pump will be most efficient in mild conditions, and decline in efficiency on very cold days.
where is the amount of energy the system gains by heating, is the temperature of the surroundings, and is the change in entropy. The equal sign refers to a reversible process , which is an imagined idealized theoretical limit, never actually occurring in physical reality, with essentially equal temperatures of system and surroundings.