Velocity head can be an important factor when testing pumps in the field. At a flow velocity of 8 feet per second, the velocity head is just 1 foot, but it increases exponentially with any increase in flow velocity. Joe Evans is responsible for customer and employee education at PumpTech, Inc., a pump and packaged system manufacturer and ...
friction head, which I have calculated and will advise for this example to be 3.2 feet; velocity head, normally a negligible factor and for simplicity we will skip it this month and address in a later article in the series; Calculate the NPSHa for a Flooded Suction: Back to the formula (yes I slipped it into the article).
the velocity head in the pipe at the gauge connection should be added to obtain total (stagnation) pressure. For a reciprocating pump (and some rotaries), the acceleration head must be subtracted. (More on acceleration head later.) Vapor Pressure: The Second Half of the NPSH Equation Vapor pressure is more difficult to determine than suction ...
Velocity Head (h v) Velocity head is the energy of a liquid as a result of its motion at some velocity (V). It is the equivalent head in feet through which the water would have to fall to acquire the same velocity or, in other words, the head necessary to accelerate the water. Velocity head can be calculated using the following formula: Where:
The velocity head is based on the relationship shown in Equation 1. Where. v = Fluid velocity (feet per second) g = Local gradational constant (feet per second 2) When fluid flows through valves and fittings, a pressure drop and resulting head loss occur.
by Lev Nelik. 07/23/2012. For a quick estimate of pump head in the field, the discharge pressure gauge is read. This number is multiplied by 2.31, and operators can get a rough value of the pump head. If the gauge reading is 80 psig gauge, then: Head = 80 x 2.31 = 185 feet. Knowing the head and having a performance curve available, you can read ...
The velocity head correction is a bit more complicated. Since it involves the difference in velocity in the pipes between the location of the suction and discharge gauges, it can be significant. Most process pumps have relatively high velocities at the suction and discharge flanges, as in your example.
Hv, or velocity head, is the kinetic energy of a mass of water moving at some velocity V. It is equivalent to the distance that water would have to fall in order to reach that velocity. It can be calculated by determining the velocity in the suction piping from a velocity table and substituting that value for V in the equation "h = V 2 /2g ...
Again, there are three dynamic factors we are concerned with inside the pipe of a dynamic system (dynamic simply means the liquid is flowing): there is the force of static pressure. there is the head (kinetic energy) due to the velocity of the liquid. there is the head (potential energy) due to an elevation change above the reference datum.
the static head, or height difference, between the liquid level in Tank A and the liquid level in Tank B; the friction head, or the pressure losses caused by the flow of liquid through the pipe and fittings, between Tank A and Tank B. In the example, the velocity head will balance out to zero, as centrifugal pumps provide pulsation-free flow.