enow.com Web Search

  1. Ads

    related to: omron brachial cuff

Search results

  1. Results from the WOW.Com Content Network
  2. Sphygmomanometer - Wikipedia

    en.wikipedia.org/wiki/Sphygmomanometer

    A sphygmomanometer (/ ˌ s f ɪ ɡ m oʊ m ə ˈ n ɒ m ɪ t ə r / SFIG-moh-mə-NO-mi-tər), also known as a blood pressure monitor, or blood pressure gauge, is a device used to measure blood pressure, composed of an inflatable cuff to collapse and then release the artery under the cuff in a controlled manner, [1] and a mercury or aneroid manometer to measure the pressure.

  3. Auscultatory gap - Wikipedia

    en.wikipedia.org/wiki/Auscultatory_gap

    An auscultatory gap, also known as the silent gap, [1] is a period of diminished or absent Korotkoff sounds during the manual measurement of blood pressure.It is associated with peripheral blood flow caused by changes in the pulse wave. [2]

  4. Blood pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Blood_pressure_measurement

    When blood flow is present, but restricted, the cuff pressure, which is monitored by the pressure sensor, will vary periodically in synchrony with the cyclic expansion and contraction of the brachial artery, i.e., it will oscillate. Over the deflation period, the recorded pressure waveform forms a signal known as the cuff deflation curve.

  5. Pulse wave velocity - Wikipedia

    en.wikipedia.org/wiki/Pulse_wave_velocity

    The theory of the velocity of the transmission of the pulse through the circulation dates back to 1808 with the work of Thomas Young. [9] The relationship between pulse wave velocity (PWV) and arterial wall stiffness can be derived from Newton's second law of motion (=) applied to a small fluid element, where the force on the element equals the product of density (the mass per unit volume ...

  6. Korotkoff sounds - Wikipedia

    en.wikipedia.org/wiki/Korotkoff_sounds

    As the pressure in the cuff is the same as the pressure produced by the heart, some blood will be able to pass through the upper arm when the pressure in the artery rises during systole. This blood flows in spurts as the pressure in the artery rises above the pressure in the cuff and then drops back down beyond the cuffed region, resulting in ...

  7. Brachial artery - Wikipedia

    en.wikipedia.org/wiki/Brachial_artery

    The brachial artery is the major blood vessel of the (upper) arm. It is the continuation of the axillary artery beyond the lower margin of teres major muscle . It continues down the ventral surface of the arm until it reaches the cubital fossa at the elbow .

  8. Ankle–brachial pressure index - Wikipedia

    en.wikipedia.org/wiki/Ankle–brachial_pressure...

    The blood pressure cuff is then slowly deflated. When the artery's pulse is re-detected through the Doppler probe the pressure in the cuff at that moment indicates the systolic pressure of that artery. [citation needed] The higher systolic reading of the left and right arm brachial artery is generally used in the

  9. Omron - Wikipedia

    en.wikipedia.org/wiki/OMRON

    Omron was established by Kazuma Tateisi (立石一真) in 1933 (as the Tateisi Electric Manufacturing Company) and incorporated in 1948. The company originated in an area of Kyoto called "Omuro (御室) ", from which the name "Omron" was derived. Prior to 1990, the corporation was known as Omron Tateisi Electronics. During the 1980s and early ...

  1. Ads

    related to: omron brachial cuff