enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Potentiometric sensor - Wikipedia

    en.wikipedia.org/wiki/Potentiometric_sensor

    Type III sensors make the electrode concept even more confusing. With respect to the design of a solid state sensor, the auxiliary phase looks as part of the electrode. But it cannot be an electrode because auxiliary phase materials are not generally good electrical conductor. In spite of this confusion, type III design offers more feasibility ...

  3. Electroanalytical methods - Wikipedia

    en.wikipedia.org/wiki/Electroanalytical_methods

    Potentiometry passively measures the potential of a solution between two electrodes, affecting the solution very little in the process. One electrode is called the reference electrode and has a constant potential, while the other one is an indicator electrode whose potential changes with the sample's composition. Therefore, the difference in ...

  4. Potentiometric titration - Wikipedia

    en.wikipedia.org/wiki/Potentiometric_titration

    Reference electrodes generally used are hydrogen electrodes, calomel electrodes, and silver chloride electrodes. The indicator electrode forms an electrochemical half-cell with the interested ions in the test solution. The reference electrode forms the other half-cell. The overall electric potential is calculated as

  5. pH meter - Wikipedia

    en.wikipedia.org/wiki/PH_meter

    The design of the electrodes is the key part: These are rod-like structures usually made of glass, with a bulb containing the sensor at the bottom. The glass electrode for measuring the pH has a glass bulb specifically designed to be selective to hydrogen-ion concentration.

  6. Ion-selective electrode - Wikipedia

    en.wikipedia.org/wiki/Ion-selective_electrode

    An ion-selective electrode (ISE), also known as a specific ion electrode (SIE), is a simple membrane-based potentiometric device which measures the activity of ions in solution. [1] It is a transducer (or sensor) that converts the change in the concentration of a specific ion dissolved in a solution into an electrical potential. ISE is a type ...

  7. Karl Fischer titration - Wikipedia

    en.wikipedia.org/wiki/Karl_Fischer_titration

    In other words, 2 moles of electrons are consumed per mole of water. 2 I − → I 2 + 2 e − B·I 2 + B·SO 2 + B + H 2 O → 2 BH + I − + BSO 3 BSO 3 + ROH → BHRSO 4. The end point is detected most commonly by a bipotentiometric titration method. A second pair of Pt electrodes is immersed in the anode solution.

  8. Electrical conductivity meter - Wikipedia

    en.wikipedia.org/wiki/Electrical_conductivity_meter

    The liquid passing through a channel in the sensor forms one turn in the secondary winding of the transformer. The induced current is the output of the sensor. Another way is to use four-electrode conductivity sensors that are made from corrosion-resistant materials.

  9. Voltammetry - Wikipedia

    en.wikipedia.org/wiki/Voltammetry

    Potential as a function of time for anodic stripping voltammetry Three-electrode setup: (1) working electrode; (2) counter electrode; (3) reference electrode. Voltammetry experiments investigate the half-cell reactivity of an analyte. Voltammetry is the study of current as a function of applied potential. These curves I = f(E) are called ...