enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Reinforced concrete structures durability - Wikipedia

    en.wikipedia.org/wiki/Reinforced_concrete...

    To assess some of the durability design parameters, the use of accelerated laboratory test is suggested, such as the so called Rapid Chloride Migration Test to evaluate chloride penetration resistance of concrete [11] '. Through the application of corrective parameters, the long-term behaviour of the structure in real exposure conditions may be ...

  3. Flow table test - Wikipedia

    en.wikipedia.org/wiki/Flow_table_test

    The flow table test or slump-flow test is a method to determine consistency of fresh concrete. Flow table test is also used to identify transportable moisture limit of solid bulk cargoes. [ 1 ] It is used primarily for assessing concrete that is too fluid (workable) to be measured using the slump test , because the concrete will not retain its ...

  4. Schmidt hammer - Wikipedia

    en.wikipedia.org/wiki/Schmidt_hammer

    The test hammer hits the concrete at a defined energy. Its rebound is dependent on the hardness of the concrete and is measured by the test equipment. By reference to a conversion chart, the rebound value can be used to determine the concrete's compressive strength. When conducting the test, the hammer should be held at right angles to the ...

  5. Concrete slump test - Wikipedia

    en.wikipedia.org/wiki/Concrete_slump_test

    The test is carried out using a metal mould in the shape of a conical frustum known as a slump cone or Abrams cone, that is open at both ends and has attached handles.The tool typically has an internal diameter of 100 millimetres (3.9 in) at the top and of 200 millimetres (7.9 in) at the bottom with a height of 305 millimetres (12.0 in).The cone is placed on a hard non-absorbent surface.

  6. Los Angeles abrasion test - Wikipedia

    en.wikipedia.org/wiki/Los_Angeles_abrasion_test

    The test reports loss of mass to abrasion and impact, expressed as a percentage of initial sample mass. [7] Maximum acceptable loss for the base course of the road is 45%; the more demanding surface course must be 35% or less. [1] The test was developed by the city engineers of Los Angeles in the 1920s. [8]

  7. Maintenance testing - Wikipedia

    en.wikipedia.org/wiki/Maintenance_testing

    Maintenance testing is a test that is performed to either identify equipment problems, diagnose equipment problems, or confirm that repair measures have been effective. It can be performed at either the system level (e.g., the HVAC system), the equipment level (e.g., the blower in an HVAC line), or the component level (e.g., a control chip in the control box for the blower in the HVAC line).

  8. Pile integrity test - Wikipedia

    en.wikipedia.org/wiki/Pile_integrity_test

    Pile integrity testing using low-strain tests such as the TDR (Transient Dynamic Response) method, is a rapid way of assessing the continuity and integrity of concrete piled foundations. The test measures: pile length, or depth to anomalies; pile head stiffness; pile shaft mobility, which is dependent on pile section and concrete properties

  9. Thermal integrity profiling - Wikipedia

    en.wikipedia.org/wiki/Thermal_integrity_profiling

    Thermal Integrity Profiling (TIP) is a non-destructive testing method used to evaluate the integrity of concrete foundations. It is standardized by ASTM D7949 - Standard Test Methods for Thermal Integrity Profiling of Concrete Deep Foundations. The testing method was first developed in the mid 1990s at the University of South Florida.