enow.com Web Search

  1. Ads

    related to: clamp on dc current sensor ic

Search results

  1. Results from the WOW.Com Content Network
  2. Clamper (electronics) - Wikipedia

    en.wikipedia.org/wiki/Clamper_(electronics)

    A positive clamp circuit (negative peak clamper) outputs a purely positive waveform from an input signal; it offsets the input signal so that all of the waveform is greater than 0 V. A negative clamp is the opposite of this—this clamp outputs a purely negative waveform from an input signal.

  3. Current clamp - Wikipedia

    en.wikipedia.org/wiki/Current_clamp

    The clamp measures the current and other circuitry the voltage; the true power is the product of the instantaneous voltage and current integrated over a cycle. Comprehensive meters designed to measure many parameters of electrical energy ( power factor , distortion , instantaneous power as a function of time, phase relationships, etc.), use ...

  4. Current sensing - Wikipedia

    en.wikipedia.org/wiki/Current_sensing

    The design of the saturable inductor current sensor is similar to that of a closed-loop Hall-effect current sensor; the only difference is that this method uses the saturable inductor instead of the Hall-effect sensor in the air gap. Saturable inductor current sensor is based on the detection of an inductance change. The saturable inductor is ...

  5. Shunt (electrical) - Wikipedia

    en.wikipedia.org/wiki/Shunt_(electrical)

    Some alternatives to shunts can provide isolation from the high voltage by not directly connecting the meter to the high voltage circuit. Examples of devices that can provide this isolation are Hall effect current sensors and current transformers (see clamp meters). Current shunts are considered more accurate and cheaper than Hall effect devices.

  6. Rogowski coil - Wikipedia

    en.wikipedia.org/wiki/Rogowski_coil

    A Rogowski coil is a toroid of wire used to measure an alternating current I(t) through a cable encircled by the toroid. The picture shows a Rogowski coil encircling a current-carrying cable. The output of the coil, v(t), is connected to a lossy integrator circuit to obtain a voltage V out (t) that is proportional to I(t).

  7. Four-terminal sensing - Wikipedia

    en.wikipedia.org/wiki/Four-terminal_sensing

    Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...