Search results
Results from the WOW.Com Content Network
When a medical device is organized into a lower class, and therefore a lower risk, it will be reviewed less stringent and be able to move into the medical field and market much quicker than devices that have high risk and must prove safety to risk benefits. [22] Classes of biomedical instruments include: Quantity Sensed: pressure, flow, temperature
Blood pressure can be measured either invasively through an inserted blood pressure transducer assembly, or noninvasively with an inflatable blood pressure cuff. Respiratory monitoring, such as: Pulse oximetry which involves measurement of the saturated percentage of oxygen in the blood, referred to as SpO2, and measured by an infrared finger cuff
Faster shunt flow results in greater temperature decreases. If the shunt is not flowing, the cooled fluid remains upstream and no temperature drop is recorded. [2] The sensor is connected to a laptop or tablet computer running ShuntCheck software. The sensor is connected to a laptop or tablet computer running ShuntCheck software.
Smartphones may be used as medical tricorders; smartphone software and camera detect pulse from a fingertip using a technique similar to that of a pulse oximeters.. A medical tricorder is a handheld [1] portable [2] scanning device to be used by consumers [3] to self-diagnose medical conditions [4] within seconds [3] and take basic vital measurements.
A spirometer measures ventilation, the movement of air into and out of the lungs. The spirogram will identify two different types of abnormal ventilation patterns, obstructive and restrictive. There are various types of spirometers that use a number of different methods for measurement (pressure transducers, ultrasonic, water gauge).
The intra-aortic balloon pump (IABP) is a mechanical device that increases myocardial oxygen perfusion and indirectly increases cardiac output through afterload reduction. It consists of a cylindrical polyurethane balloon that sits in the aorta , approximately 2 centimeters (0.79 in) from the left subclavian artery . [ 1 ]
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
The balloon, when inflated, causes the catheter to "wedge" in a small pulmonary blood vessel. So wedged, the catheter can provide an indirect measurement of the pressure in the left atrium of the heart, showing a mean pressure, in addition to a, x, v, and y waves which have implications for status of the left atria and the mitral valve.