enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Soil liquefaction - Wikipedia

    en.wikipedia.org/wiki/Soil_liquefaction

    A typical reference strain for the approximate occurrence of zero effective stress is 5% double amplitude shear strain. This is a soil test-based definition, usually performed via cyclic triaxial, cyclic direct simple shear, or cyclic torsional shear type apparatus. These tests are performed to determine a soil's resistance to liquefaction by ...

  3. Eurocode 2: Design of concrete structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_2:_Design_of...

    Logo of Eurocode 2 An example of a concrete structure. In the Eurocode series of European standards (EN) related to construction, Eurocode 2: Design of concrete structures (abbreviated EN 1992 or, informally, EC 2) specifies technical rules for the design of concrete, reinforced concrete and prestressed concrete structures, using the limit state design philosophy.

  4. Prestressed concrete - Wikipedia

    en.wikipedia.org/wiki/Prestressed_concrete

    Prestressed beam with load. Prestressed concrete is a form of concrete used in construction. It is substantially "prestressed" (compressed) during production, in a manner that strengthens it against tensile forces which will exist when in service. [1][2]: 3–5 [3] It was patented by Eugène Freyssinet in 1928. [4]

  5. Eurocode 8: Design of structures for earthquake resistance

    en.wikipedia.org/wiki/Eurocode_8:_Design_of...

    In the Eurocode series of European standards (EN) related to construction, Eurocode 8: Design of structures for earthquake resistance (abbreviated EN 1998 or, informally, EC 8) describes how to design structures in seismic zone, using the limit state design philosophy. It was approved by the European Committee for Standardization (CEN) on 23 ...

  6. List of EN standards - Wikipedia

    en.wikipedia.org/wiki/List_of_EN_standards

    EN 1994: (Eurocode 4) Design of composite steel and concrete structures; EN 1995: (Eurocode 5) Design of timber structures; EN 1996: (Eurocode 6) Design of masonry structures; EN 1997: (Eurocode 7) Geotechnical design; EN 1998: (Eurocode 8) Design of structures for earthquake resistance; EN 1999: (Eurocode 9) Design of aluminium structures

  7. Bearing capacity - Wikipedia

    en.wikipedia.org/wiki/Bearing_capacity

    Bearing capacity. In geotechnical engineering, bearing capacity is the capacity of soil to support the loads applied to the ground. The bearing capacity of soil is the maximum average contact pressure between the foundation and the soil which should not produce shear failure in the soil. Ultimate bearing capacity is the theoretical maximum ...

  8. Eurocode: Basis of structural design - Wikipedia

    en.wikipedia.org/wiki/Eurocode:_Basis_of...

    Eurocode 0 is intended to be used in conjunction with EN 1991 to EN 1999 for the structural design of buildings and civil engineering works, including geotechnical aspects, structural fire design, situations involving earthquakes, execution and temporary structures. Eurocode 0 is also applicable: for the structural appraisal of existing ...

  9. Shear strength - Wikipedia

    en.wikipedia.org/wiki/Shear_strength

    In engineering, shear strength is the strength of a material or component against the type of yield or structural failure when the material or component fails in shear. A shear load is a force that tends to produce a sliding failure on a material along a plane that is parallel to the direction of the force. When a paper is cut with scissors ...