    Interference mitigation and hence electromagnetic compatibility may be achieved by addressing any or all of these issues, i.e., quieting the sources of interference, inhibiting coupling paths and/or hardening the potential victims. In practice, many of the engineering techniques used, such as grounding and shielding, apply to all three issues.

  3. Electromagnetic shielding - Wikipedia

    en.wikipedia.org/wiki/Electromagnetic_shielding

    Common sheet metals for shielding include copper, brass, nickel, silver, steel, and tin. Shielding effectiveness, that is, how well a shield reflects or absorbs/suppresses electromagnetic radiation, is affected by the physical properties of the metal. These may include conductivity, solderability, permeability, thickness, and weight.

  4. Shielded cable - Wikipedia

    en.wikipedia.org/wiki/Shielded_cable

    The best way to wire shielded cables for screening is to ground the shield at both ends of the cable. [6] Traditionally there existed a rule of thumb to ground only the source end of the shield to avoid ground loops. Best practice is to ground at both ends, but there is a possibility of ground loops.

  5. Grounding - Wikipedia

    en.wikipedia.org/wiki/Grounding

    Grounding, a strategy for coping with stress or other negative emotions; Grounding in communication, the collection of mutual knowledge, beliefs, and assumptions; "common ground" Ground (electricity), a common return path for electric current; Symbol grounding problem, a problem in cognition and artificial intelligence

  6. Ground loop (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_loop_(electricity)

    The ground loop still exists, but the two sides of the loop are close together, so stray magnetic fields induce equal currents in both sides, which cancel out. Break in the shield Create a break in the signal cable shield conductor. [5] The break should be at the load end. This is often called ground lifting. It is the simplest solution; it ...

  7. TIA-607-B - Wikipedia

    en.wikipedia.org/wiki/TIA-607-B

    According to the standard, proper infrastructure bonding requires the following elements: a telecommunications main grounding busbar (TMGB), telecommunications grounding busbars (TGB), telecommunications bonding backbone (TBB), grounding equalizers (GE), and a bonding conductor for telecommunications (BCT).

  8. Parasitic capacitance - Wikipedia

    en.wikipedia.org/wiki/Parasitic_capacitance

    High-frequency circuits require special design techniques such as careful separation of wires and components, guard rings, ground planes, power planes, shielding between input and output, termination of lines, and striplines to minimize the effects of unwanted capacitance.

  9. Ground (electricity) - Wikipedia

    en.wikipedia.org/wiki/Ground_(electricity)

    A ground fault protection relay must trip the breaker to protect the circuit before overheating of the resistor occurs. High-resistance grounding (HRG) systems use an NGR to limit the fault current to 25 A or less. They have a continuous rating, and are designed to operate with a single-ground fault.