Search results
Results from the WOW.Com Content Network
References will be made to "actual" flow rate through a meter and "standard" or "base" flow rate through a meter with units such as acm/h (actual cubic meters per hour), sm 3 /sec (standard cubic meters per second), kscm/h (thousand standard cubic meters per hour), LFM (linear feet per minute), or MMSCFD (million standard cubic feet per day).
Measurement and interpretation of 2 and 3 phase multiphase flow can also be achieved by using alternative flow measurement technologies such as SONAR.SONAR meters apply the principles of underwater acoustics to measure flow regimes and; can be clamped on to wellheads and flow lines to measure the bulk (mean) fluid velocity of the total mixture which is then post-processed and analyzed along ...
The mass flow of a U-shaped Coriolis flow meter is given as: Q m = K u − I u ω 2 2 K d 2 τ {\displaystyle Q_{m}={\frac {K_{u}-I_{u}\omega ^{2}}{2Kd^{2}}}\tau } where K u is the temperature dependent stiffness of the tube, K is a shape-dependent factor, d is the width, τ is the time lag, ω is the vibration frequency, and I u is the inertia ...
The flow rate is specified as a percentage of its calibrated full scale flow and is supplied to the MFC as a voltage signal. Mass flow controllers require the supply gas or liquid to be within a specific pressure range. Low pressure will starve the MFC of fluid and cause it to fail to achieve its setpoint. High pressure may cause erratic flow ...
SCADA (an acronym for supervisory control and data acquisition) is a control system architecture comprising computers, networked data communications and graphical user interfaces for high-level supervision of machines and processes.
A velocity-type meter measures the velocity of flow through a meter of known internal capacity. The speed of the flow can then be converted into a volume of flow to determine the usage. There are several types of meters that measure water flow velocity, including jet meters (single-jet and multi-jet), turbine meters, propeller meters and mag ...
A positive displacement meter is a type of flow meter that requires fluid to mechanically displace components in the meter in order for flow measurement. Positive displacement (PD) flow meters measure the volumetric flow rate of a moving fluid or gas by dividing the media into fixed, metered volumes (finite increments or volumes of the fluid).
A vortex flowmeter has the following components: A flow sensor operable to sense pressure variations due to vortex-shedding of a fluid in a passage and to convert the pressure variations to a flow sensor signal, in the form of an electrical signal; and a signal processor operable to receive the flow sensor signal and to generate an output signal corresponding to the pressure variations due to ...