If the equilibrium for the reaction lies far to the right (i.e. a stoichiometric equilibrium has been achieved), then when all analyte has been reacted by the titrant continuing addition of titrant will be revealed by a sharp break in the temperature/volume curve. Figures 1a and 1b illustrate idealized examples. Fig. 2.
A reagent, termed the titrant or titrator, [2] is prepared as a standard solution of known concentration and volume. The titrant reacts with a solution of analyte (which may also be termed the titrand [3]) to determine the analyte's concentration. The volume of titrant that reacted with the analyte is termed the titration volume.
Figure 2 gives an example; in this example, the two x-intercepts differ by about 0.2 mL but this is a small discrepancy, given the large equivalence volume (0.5% error). Similar equations can be written for the titration of a weak base by strong acid (Gran, 1952; Harris, 1998).
The ratio of peak areas between the internal standard and analyte is calculated to determine analyte concentration. [12] A common type of internal standard is an isotopically labeled analogue of the analyte, which incorporates one or more atoms of 2 H, 13 C, 15 N and 18 O into its structure. [13]
The volumetric titration is based on the same principles as the coulometric titration, except that the anode solution above now is used as the titrant solution. The titrant consists of an alcohol (ROH), base (B), SO 2 and a known concentration of I 2. Pyridine has been used as the base in this case. One mole of I 2 is consumed for each mole of ...
The gas constant occurs in the ideal gas law: = = where P is the absolute pressure, V is the volume of gas, n is the amount of substance, m is the mass, and T is the thermodynamic temperature. R specific is the mass-specific gas constant. The gas constant is expressed in the same unit as molar heat.
Depending on whether the reaction between the titrant and analyte is exothermic or endothermic, the temperature will either rise or fall during the titration. When all analyte has been consumed by reaction with the titrant, a change in the rate of temperature increase or decrease reveals the equivalence point and an inflection in the ...
The electrochemical generation of a titrant is much more sensitive and can be much more accurately controlled than the mechanical addition of titrant using a burette drive. For example, a constant current flow of 10 μA for 100 ms is easily generated and corresponds to about 10 micrograms of titrant.