13 – Prism scale knob. A lensmeter or lensometer (sometimes even known as focimeter or vertometer), [1] [2] is an optical instrument used in ophthalmology. It is mainly used by optometrists and opticians to measure the back or front vertex power of a spectacle lens and verify the correct prescription in a pair of eyeglasses, to properly ...
In some offices, this process is used to provide the starting point for the ophthalmologist or optometrist in subjective refraction tests. Here, lenses are switched in and out of a phoropter and the patient is asked "which looks better" while looking at a chart.
Knapp's rule. Knapp's Rule states that lenses placed at the anterior focal point of the eye, generally 15 mm in front of the eye, will create similarly sized images on the retina, whenever the disparity between the two eyes is due to a difference in axial length of the eyes. [1]
Lens clock. A lens clock is a mechanical dial indicator that is used to measure the dioptric power of a lens.It is a specialized version of a spherometer.A lens clock measures the curvature of a surface, but gives the result as an optical power in diopters, assuming the lens is made of a material with a particular refractive index.
Prism dioptres. Prism correction is commonly specified in prism dioptres, a unit of angular measurement that is loosely related to the dioptre. Prism dioptres are represented by the Greek symbol delta (Δ) in superscript. A prism of power 1 Δ would produce 1 unit of displacement for an object held 100 units from the prism. [2]
The polarimeter is made up of two Nicol prisms (the polarizer and analyzer). The polarizer is fixed and the analyzer can be rotated. The prisms may be thought of as slits S1 and S2. The light waves may be considered to correspond to waves in the string. The polarizer S1 allows only those light waves which move in a single plane.
A second peg, below it, can be moved back and forth until it is just detectably nearer than the fixed one. Stereoacuity is defined as the minimum angle detectable, calculated as the difference between the angles subtended by both positions, A and B. Stereoacuity is possible due to binocular disparity, i.e., the difference in their binocular ...
The prism cover test ( PCT) is an objective measurement and the gold standard in measuring strabismus, i.e. ocular misalignment, or a deviation of the eye. [1] It is used by ophthalmologists and orthoptists in order to measure the vertical and horizontal deviation and includes both manifest and latent components. [1]