  2. Aluminum Conductors | Information by Electrical Professionals for...

    forums.mikeholt.com/threads/aluminum-conductors.2572207

    Typically because that is what the specifications required. As far as I know, there are no aluminum conductors smaller than 8AWG on the market at this time. You can get 12 and 10 AWG in Copper-Clad- Aluminum in both single conductor and NM cable at this time. The only real issue with the use of CCA is wire connections.

  3. aluminum in house wiring | Information by Electrical...

    forums.mikeholt.com/threads/aluminum-in-house-wiring.16856

    Re: aluminum in house wiring There were several components to aluminum wiring failures: 1. Reynolds was making wire that was a very soft alloy compared to Alcan's Stabiloy(R). Electrical conductor aluminum needs to be 99% or better purity but must also contain a dash of silicon and magnesium to not be to soft to withstand normal joint pressure. 2.

  4. Aluminum Repairs or pigtailing | Information by Electrical ...

    forums.mikeholt.com/threads/aluminum-repairs-or-pigtailing.85380

    Copalum permanently connects old technology aluminum wire to a short length of copper wire. The copper wire is then terminated to outlets, fixtures and appliances. Citizens is still researching the potential for CO/ALR connectors to be considered as a third insurable alternative method:-- CO/ALR: The name means copper-aluminum revised.

  5. aluminum wiring | Information by Electrical Professionals for ...

    forums.mikeholt.com/threads/aluminum-wiring.2979

    Re: aluminum wiring I thought that you Rent the tool, not buy it. Around here, they charge $80 per opening. So a 3-gang box costs $240. Now the kicker is all of the devices might not fit back into the box, so for an Extra Charge they will rip the wall apart and install a bigger box, or they will install a surface-mount Deep wiremold e

  6. mobile home & ground rods | Information by Electrical...

    forums.mikeholt.com/threads/mobile-home-ground-rods.91882

    Dec 6, 2011. #3. No ground rods required for a mobile home. At the service, yes, but not at the actual trailer. Section 550.10 outlines the requirements for mobile home feeders and connection. No where does it require any ground rod, or grounding electrode systems. Section 550.16 outlines the grounding requirements for mobile homes.

  7. aluminum wiring vs copper | Information by Electrical...

    forums.mikeholt.com/threads/aluminum-wiring-vs-copper.2552865

    Apr 6, 2020. #20. Well being in the electrical preventive maintenance (PM) business we find that the creep characteristic under pressure between aluminum and copper wire is different. It is greater with aluminum than with copper and we see evidence of this during the torquing of cable lug and bus connections.

  8. Service and Sub panel feeders on a budget

    forums.mikeholt.com/threads/service-and-sub-panel-feeders-on-a-budget.150888

    The Mobile Home Feeder cable is almost identical to standard URD Aluminum except for a couple things. It has a neutral AND a ground wire where URD usually only has the neutral for use as a feed from the utility transformer to the service disconnect.

  9. An aluminum wiring mobile home went on fire. I took permits for repairs, one for FAS Alteration and one for feeder and the rods. My plan was: first installing the rods and call for inspection for those and the feeder, that according to me it is acceptable for this service. The existing rod (only...

  10. Mobil Home Feeder | Information by Electrical Professionals for...

    forums.mikeholt.com/threads/mobil-home-feeder.2563614

    Bare conductors are not allowed in underground installations, even for the EGC. If the feeder is installed above ground, there may be concern for a higher probability of mechanical damage to the feeder going into a mobile home (versus other kinds of buildings). FYI, here is the response from Southwire.

  11. Aluminum wire | Information by Electrical Professionals for...

    forums.mikeholt.com/threads/aluminum-wire.8067

    Re: Aluminum wire proper termination practice is the problem with aluminum wire. and if these practices were known back in the seventies, when many homes were wired with aluminum branch circuit conductors, there would be alot less problems with it. but then, the labor required to properly terminate it might have been weighed by the contractor and copper might have been cheaper? load conditions ...