Ad
related to: hose strain relief spring pressure rating tool kit
Search results
Results from the WOW.Com Content Network
Either the flow-rate or the pressure drop are fixed and the other measured. Knowing the dimensions, the flow-rate can be converted into a value for the shear rate and the pressure drop into a value for the shear stress. Varying the pressure or flow allows a flow curve to be determined.
A relief valve DN25 on cooling water pipe from heat exchanger Schematic diagram of a conventional spring-loaded pressure relief valve. A relief valve or pressure relief valve (PRV) is a type of safety valve used to control or limit the pressure in a system; excessive pressure might otherwise build up and create a process upset, instrument or equipment failure, explosion, or fire.
Plane-strain compression testing is typically used for measuring mechanical properties and for exploring microstructure development in the course of thermomechanical treatment. [4] During the test the specimen is placed between the punches and the constrain plates.
The Hopkinson pressure bar was first suggested by Bertram Hopkinson in 1914 [1] as a way to measure stress pulse propagation in a metal bar. Later, in 1949 Herbert Kolsky [2] refined Hopkinson's technique by using two Hopkinson bars in series, now known as the split-Hopkinson bar, to measure stress and strain, incorporating advancements in the cathode ray oscilloscope in conjunction with ...
A rupture disc (burst) Pressure-effect acting at a rupture disc A rupture disc, also known as a pressure safety disc, burst disc, bursting disc, or burst diaphragm, is a non-reclosing pressure relief safety device that, in most uses, protects a pressure vessel, equipment or system from overpressurization or potentially damaging vacuum conditions.
A typical nominal regulated gauge pressure from a medical oxygen regulator is 3.4 bars (50 psi), for an absolute pressure of approximately 4.4 bar and a pressure ratio of about 4.4 without back pressure, so they will have choked flow in the metering orifices for a downstream (outlet) pressure of up to about 2.3 bar absolute.
Note: Type R is a designation, rather than a true "type". The R designation specifies a presser foot diameter (hence the R, for radius; obviously D could not be used) of 18 ± 0.5 mm (0.71 ± 0.02 in) in diameter, while the spring forces and indenter configurations remain unchanged.
An example of an electrical force gauge is an "electronic scale". One or more electrical load cells (commonly referred to as "weigh bars") are used to support a vertical or horizontal "live load" and are solid-state potentiometers which have variable internal resistance proportional to the load they are subjected to and deflected by.
Ad
related to: hose strain relief spring pressure rating tool kit