enow.com Web Search

  1. Ads

    related to: goodman evaporator coil leak check

Search results

  1. Results from the WOW.Com Content Network
  2. Thermal expansion valve - Wikipedia

    en.wikipedia.org/wiki/Thermal_expansion_valve

    Also, TX valve air conditioning systems do not require an accumulator (a refrigerant tank placed downstream of the evaporator's outlet), since the valves reduce the liquid refrigerant flow when the evaporator's thermal load decreases, so that all the refrigerant completely evaporates inside the evaporator (in normal operating conditions such as ...

  3. Condensate pump - Wikipedia

    en.wikipedia.org/wiki/Condensate_pump

    If the outlet of the line is at a higher level than the tank of the pump, a check valve is often fitted at the outlet of the pump so that liquid cannot flow backwards into the pump's tank. If the outlet is below the tank level, siphonage usually naturally clears the output line of all liquid when the pump is de-energized.

  4. Air conditioning - Wikipedia

    en.wikipedia.org/wiki/Air_conditioning

    This is partly because ice forms on the outdoor unit's heat exchanger coil, which blocks air flow over the coil. To compensate for this, the heat pump system must temporarily switch back into the regular air conditioning mode to switch the outdoor evaporator coil back to the condenser coil, to heat up and defrost. Therefore, some heat pump ...

  5. Internally grooved copper tube - Wikipedia

    en.wikipedia.org/wiki/Internally_grooved_copper_tube

    Grooved coils facilitate more efficient heat transfer than smooth coils. [1] [2] Small diameter coils have better rates of heat transfer than conventionally-sized condenser and evaporator coils with round copper tubes and aluminum or copper fin that have been the standard in the HVAC industry for many years. Small diameter coils can withstand ...

  6. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    Duct leakage test in the US. A duct leakage tester is a diagnostic tool designed to measure the airtightness of forced air heating, ventilating and air-conditioning (HVAC) ductwork. A duct leakage tester consists of a calibrated fan for measuring an air flow rate and a pressure sensing device to measure the pressure created by the fan flow.

  7. Air source heat pump - Wikipedia

    en.wikipedia.org/wiki/Air_source_heat_pump

    The main components of a split-system (called split as there are both inside and outside coils) air source heat pump are: An outdoor evaporator heat exchanger coil, which extracts heat from ambient air; One or more [9] indoor condenser heat exchanger coils. They transfer the heat into the indoor air, or an indoor heating system such as water ...

  8. Evaporator - Wikipedia

    en.wikipedia.org/wiki/Evaporator

    An evaporator is a type of heat exchanger device that facilitates evaporation by utilizing conductive and convective heat transfer, which provides the necessary thermal energy for phase transition from liquid to vapour. Within evaporators, a circulating liquid is exposed to an atmospheric or reduced pressure environment causing it to boil at a ...

  9. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.

  1. Ads

    related to: goodman evaporator coil leak check