Search results
Results from the WOW.Com Content Network
This fitting (also known as a "bungalow fitting" or a "cottage fitting") is a sanitary tee that allows two trap arms to be connected at the same level. A toilet is the main connection, with the option of a right or left-hand outlet to the 3" inlet with a choice of 1-1/2" or 2" in size.
While pipe sizes in Australia are inch-based, they are classified by outside rather than inside diameter (e.g., a nominal 3 ⁄ 4 inch copper pipe in Australia has measured diameters of 0.750 inches outside and 0.638 inches inside, whereas a nominal 3 ⁄ 4 inch copper pipe in the U.S. and Canada has measured diameters of 0.875 inch outside and ...
A Fixture Unit is not a flow rate unit but a design factor. A fixture unit is equal to 1 cubic foot (0.028 m 3) of water drained in a 1 + 1 ⁄ 4 inches (32 mm) diameter pipe over one minute. [2] One cubic foot of water is roughly 7.48 US gallons (28.3 L; 6.23 imp gal). A Fixture Unit is used in plumbing design for both water supply and waste ...
Wire sized 1 AWG is referred to as "one gauge" or "No. 1" wire; similarly, thinner sizes are pronounced "x gauge" or "No. x" wire, where x is the positive-integer AWG number. Consecutive AWG wire sizes thicker than No. 1 wire are designated by the number of zeros: No. 0, often written 1/0 and referred to as "one-aught" or "single-aught" wire
In addition to lengths of pipe or tubing, pipe fittings such as valves, elbows, tees, and unions. are used in plumbing systems. [40] Pipe and fittings are held in place with pipe hangers and strapping. Plumbing fixtures are exchangeable devices that use water and can be connected to a building's plumbing system. They are considered to be ...
Lavatories and water closets normally connect to the water supply by means of a supply, which is a tube, usually of nominal 3/8 in (United States) or 10 or 12 mm diameter (Europe and Middle East), which connects the water supply to the fixture, sometimes through a flexible hose.
All DWV systems require various sized fittings and pipes which are measured by their internal diameter of both the pipes and the fittings which, and in most cases are Schedule 40 PVC wye's, tee's, elbows ranging from 90 degrees to 22.5 degrees for both inside diameter fitment (street) as well as outer diameter fitment (hub), repair and slip ...
A chase nipple is a short pipe fitting, which creates a path for wires between two electrical boxes. A chase nipple has male threads on one end only. The other end is a hexagon. The chase nipple passes through the knockouts of two boxes, and is secured by an internally threaded ring called a lock nut. [1] [2]