enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. ASME Boiler and Pressure Vessel Code - Wikipedia

    en.wikipedia.org/wiki/ASME_Boiler_and_Pressure...

    A fire-tube boiler exploded at the Grover Shoe Factory in Brockton, Massachusetts, on March 20, 1905, which resulted in the deaths of 58 people and injured 150. Then on December 6, 1906, a boiler in the factory of the P.J. Harney Shoe Company exploded in Lynn, Massachusetts. As a result, the state of Massachusetts enacted the first legal code ...

  3. Boiler design - Wikipedia

    en.wikipedia.org/wiki/Boiler_design

    Boiler design is the process of designing boilers used for various purposes. The main function of a boiler is to heat water to generate steam. Steam produced in a boiler can be used for a variety of purposes including space heating, sterilisation, drying, humidification and power generation. The temperature or condition of steam required for ...

  4. Firebox (steam engine) - Wikipedia

    en.wikipedia.org/wiki/Firebox_(steam_engine)

    The oil burner nozzle is usually mounted in the front of the firebox, protected by a hood of firebrick, and aimed at the firebrick wall below the firebox door. Dampers control air flow to the oil fire. Schematic of a later steam locomotive firebox boiler, with firebox to the left and indicatively showing two superheater elements to the right.

  5. Fire-tube boiler - Wikipedia

    en.wikipedia.org/wiki/Fire-tube_boiler

    A fire-tube boiler is a type of boiler invented in 1828 by Mark Seguin, [1] in which hot gases pass from a fire through one or more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermal conduction , heating the water and ultimately creating steam .

  6. Belpaire firebox - Wikipedia

    en.wikipedia.org/wiki/Belpaire_firebox

    In steam boilers, the firebox is encased in a water jacket on five sides, (front, back, left, right and top) to ensure maximum heat transfer to the water. Stays are used to support the surfaces against the high pressure between the outside wall and the interior firebox wall, and partially to conduct heat into the boiler interior.

  7. Essentials of Fire Fighting - Wikipedia

    en.wikipedia.org/wiki/Essentials_of_Fire_Fighting

    The Essentials of Fire Fighting is the required training manual used in countless local fire departments and state/provincial training agencies in every region of the United States and Canada. Since the release of the first edition of this manual in 1978, more than 2.5 million copies of the Essentials of Fire Fighting have been distributed to ...

  8. Control and indicating equipment - Wikipedia

    en.wikipedia.org/wiki/Control_and_Indicating...

    The fire detection and fire alarm system subcommittee of ISO/TC 21, Equipment for Fire Protection and Fire Fighting, had oversight for development of five standards covering detectors, control and indicating equipment. ISO 7240-2:3003 specifies requirements, test methods and performance criteria for control and indicating equipment (c.i.e.) for ...

  9. OpenTherm - Wikipedia

    en.wikipedia.org/wiki/OpenTherm

    OpenTherm was founded in 1996 because multiple manufacturers needed a simple-to-use communicating system between room controller and boiler. It had to run, like the existing controllers, over the existing two wires, not polarity sensitive, without the use of batteries.