  1. Results from the WOW.Com Content Network
  2. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    So if A–B, B–C and C–A are all 240 volts, then A–N and C–N will both be 120 volts, but B–N will be 208 volts. Other types of three-phase supplies are wye connections, ungrounded delta connections, or corner-grounded delta [2] (ghost leg configuration) connections. These connections do not supply split single-phase power, and do not ...

  3. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    Lighting and general purpose receptacles are at 120 volts AC, with larger devices fed by three wire single-phase circuits at 240 volts. In commercial construction, three-phase circuits are often used. Common 3 phase configurations within a building are 208v/120 wye, 120/240 center tapped delta and 480v/277v wye. Lighting is usually fed by 277 V ...

  4. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    They are also found on some RVs for connecting to shore power. RVs in the US are equipped for 120 V 30 A or 240 V 50 A service, and use a cord to connect to a receptacle at the campsite, usually on a power pedestal with one or more receptacles providing 120 V 30 A (TT30R), 240 V 50 A (14-50R), or 120 V 15/20 A (5-20R) service.

  5. Three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Three-phase_electric_power

    Three-phase transformer with four-wire output for 208Y/120 volt service: one wire for neutral, others for A, B and C phases. Three-phase electric power (abbreviated 3ϕ [1]) is a common type of alternating current (AC) used in electricity generation, transmission, and distribution. [2]

  6. Electric power distribution - Wikipedia

    en.wikipedia.org/wiki/Electric_power_distribution

    Closer to the customer, a distribution transformer steps the primary distribution power down to a low-voltage secondary circuit, usually 120/240 V in the US for residential customers. The power comes to the customer via a service drop and an electricity meter. The final circuit in an urban system may be less than 15 metres (50 ft) but may be ...

  7. Low-voltage network - Wikipedia

    en.wikipedia.org/wiki/Low-voltage_network

    A pole-mounted three-phase distribution transformer. Low-voltage feeders distributing power to households are placed below the transformer. A low-voltage network or secondary network is a part of electric power distribution which carries electric energy from distribution transformers to electricity meters of end customers.

  8. Service drop - Wikipedia

    en.wikipedia.org/wiki/Service_drop

    The service drop provides the building with two 120 V lines of opposite phase, so 240 V can be obtained by connecting a load between the two 120 V conductors, while 120 V loads are connected between either of the two 120 V lines and the neutral line. 240 V circuits are used for high-demand devices, such as air conditioners, water heaters ...

  9. Mains electricity by country - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity_by_country

    For example, in North America, a unique split-phase system is used to supply to most premises that works by center tapping a 240 volt transformer. This system is able to concurrently provide 240 volts and 120 volts. Consequently, this allows homeowners to wire up both 240 V and 120 V circuits as they wish (as regulated by local building codes).