This stage may switch off the HVAC equipment (preventing the production of further condensate), trigger an alarm, or both. Some systems may include two pumps to empty the tank. In this case, the two pumps often alternate operation, and a two-stage switch serves to energize the on-duty pump at the first stage and then energize the remaining pump ...
The fan coil unit will contain a purpose designed drip tray with drain connection for this purpose. The simplest means to drain the condensate from multiple fan coil units will be by a network of pipework laid to falls to a suitable point. Alternatively a condensate pump may be employed where space for such gravity pipework is limited.
A temperature switch or a thermistor can control the evaporator coil surface temperature, and a pressure switch or sensing element can monitor the suction pressure (which is in relationship with the refrigerant's evaporating temperature). Both control means can act (either directly or by means of a control unit fed by their data) upon the ...
The purpose of an air coil freeze stat is to keep the refrigerant-to-air heat exchanger (commonly called air coils) from freezing. This kind of freeze stat is typically used for heating coils which are exposed to outside air and is usually installed on the supply air side of the coil. [ 1 ]
A thermal expansion valve is a key element to a heat pump; this is the cycle that makes air conditioning, or air cooling, possible.A basic refrigeration cycle consists of four major elements: a compressor, a condenser, a metering device and an evaporator.
A run-around coil installation, serving air handling units on the roof of an office building. A run-around coil is a type of energy recovery heat exchanger most often positioned within the supply and exhaust air streams of an air handling system, or in the exhaust gases of an industrial process, to recover the heat energy. Generally, it refers ...
A semi-knocked-down kit (SKD) or incompletely disassembled kit (although it has never been assembled) is a kit of the partially assembled parts of a product. Both types of KDs, complete and incomplete, are collectively referred to within the auto industry as knocked-down export ( KDX ), and cars assembled in the country of origin and exported ...
Vapor compression distiller made by BRAM-COR (Italy) Vapor-compression evaporation is the evaporation method by which a blower, compressor or jet ejector is used to compress, and thus, increase the pressure of the vapor produced.